Friedrich 920-087-09 operation manual To Chassis Junction

Page 17

Figure 15

TO CHASSIS JUNCTION

Figure 16

 

 

STRAIGHT

 

CONNECTOR

WALL CONNECTION

JUNCTION

 

BOX

TRIM HARNESS TO LENGTH

EXPOSE WIRES (1.0 IN.)

4.0 IN.

18.0 IN.

 

GROUND

 

SCREW

GROUND

 

WIRE

 

HARNESS

 

JUNCTION

COVER

SCREWS

BOX COVER

FRP033

 

Figure 17

STRIP WIRE ENDS (0.5 IN.)

TO WALL JUNCTION

FRP032

3.Route the cut ends of harness through the conduit connector assembly and flex conduit sleeve. Be sure to use the supplied conduit bushing to prevent damage to the cord by the conduit.

The cord should pass through the Locknut, Spacer, Chassis Junction Box, Conduit Connector, Bushing, then the Conduit Sleeve. See Figure 17.

4.Route the cut ends of the power cord through the elbow connector at the other end of the conduit. Tighten screws on elbow connector to secure conduit sleeve.

5.Fasten and secure the elbow connector to the wall junction box cover with locknut. Place and mount the wall junction box with the four wall mounting screws making sure to pass the wall lines through the junction box. Connect and join all wall lines with the stripped ends using wire nuts. Tighten both screws of the wall junction box cover to junction box.

6.Follow steps 4-6 on page 19 and refer to Figure 27.

 

LEADING SIDE FOR

 

WIRE HARNESS INSERTION

SPACER

LOCKNUT

 

 

CHASSIS

 

JUNCTION

SPACER

BOX

CONDUIT

CONNECTOR

BUSHING

CONDUIT

SLEEVE

EXITING SIDE FOR

 

WIRE HARNESS

FRP034

15

Image 17
Contents Ptac Page Table of Contents Page General Instructions Read Installation Operation ManualCongratulations Installation Checklist General SpecificationsTypical Building Plan View Ptac Installation RecommendationsFor Deep Wall Installation Greater than 13 1/4 See Wall Sleeve Installation Instructions PdxwsTypical Wall Sleeve Installation Falling Object HazardPanel Wall Alternate Wall InstallationsFrame and Brick Veneer Curtain WallWall Sleeve Attachment DimensionsLintel Installation One-Piece Deep Wall Sleeve Installation PdxwsextInternal Drain Drain Kit Location and InstallationDrain Kit Installation Cover Plate InstallationDrain Tube Installation See Figure Standard Grille Pxga Standard Grille Installation InstructionsElectrical Rating Tables Power Cord Information 230/208V models onlyAll 230/208 volt units are equipped with power cords Electrical Shock Hazard Electrical Wiring for 265 Volt ModelsPower Cord Installation To Chassis Junction Suffocation Hazards Chassis Install PreparationShipping Screw Location Unit Damage HazardShipping Tape Location Securing Unit Chassis InstallationExcessive Weight Hazard Power Connection How To ConnectFriedrich Ptac Digital Control and Unit Features Page System Configuration Dip Switches Digital Control User Input ConfigurationDip Switch Setting Digital Control Operation Remote Control Thermostat Installation Energy Management Desk Control TerminalsRoutine Maintenance Complaint Cause Solution Basic TroubleshootingService & Assistance New Construction Accessories AccessoriesPxcja Room AIR Conditioners Limited Warranty Page 66129906249