Friedrich 920-087-09 operation manual System Configuration

Page 24

System Configuration

Fresh Air Vent Control

The vent control lever is located on the left side of the unit, behind the front panel.

NOTE: The vent door shipping hardware must be removed before using the vent control lever. See page 17, Figure 21, (Remove Shipping Screw from Vent Door if present).

When vent door is set to CLOSE, only the air inside the room is circulated and filtered, See Figure 28.

When vent door is set to OPEN, some outdoor air will be drawn into room. This may reduce heating or cooling efficiency.

Figure 28

 

Air Vent Control Location

VENT CONTROL

 

(Pull lever through

 

label to operate)

 

CLOSE

D

 

 

FRP025

Adjusting Air

To adjust air direction:

1.Remove front panel. See Figure 22.

2.Remove louver screws that hold louver insert in place (from back side of front panel). See Figure 29.

3.Turn louver insert and rotate 180°. See Figure 30.

4.Replace louver insert.

5.Replace screws and front panel.

Figure 29

Backside of Front Panel

LOUVER SCREWS

FRP026

Figure 30

 

Adjusting Louvers

 

AIR DISCHARGE OUTWARD (Default)

AIR DISCHARGE UPWARD

 

FRP027

22

 

Image 24
Contents Ptac Page Table of Contents Page Read Installation Operation Manual CongratulationsGeneral Instructions General Specifications Installation ChecklistPtac Installation Recommendations Typical Building Plan ViewWall Sleeve Installation Instructions Pdxws For Deep Wall Installation Greater than 13 1/4 SeeTypical Wall Sleeve Installation Falling Object HazardAlternate Wall Installations Panel WallFrame and Brick Veneer Curtain WallDimensions Wall Sleeve AttachmentOne-Piece Deep Wall Sleeve Installation Pdxwsext Lintel InstallationDrain Kit Location and Installation Internal DrainCover Plate Installation Drain Tube Installation See FigureDrain Kit Installation Pxga Standard Grille Installation Instructions Standard GrillePower Cord Information 230/208V models only All 230/208 volt units are equipped with power cordsElectrical Rating Tables Electrical Wiring for 265 Volt Models Power Cord InstallationElectrical Shock Hazard To Chassis Junction Chassis Install Preparation Suffocation HazardsUnit Damage Hazard Shipping Tape LocationShipping Screw Location Chassis Installation Excessive Weight HazardSecuring Unit How To Connect Power ConnectionFriedrich Ptac Digital Control and Unit Features Page System Configuration Digital Control User Input Configuration Dip Switch SettingDip Switches Digital Control Operation Remote Control Thermostat Installation Desk Control Terminals Energy ManagementRoutine Maintenance Basic Troubleshooting Complaint Cause SolutionService & Assistance Accessories New Construction AccessoriesPxcja Room AIR Conditioners Limited Warranty Page 66129906249