Friedrich 920-087-09 Congratulations, General Instructions, Read Installation Operation Manual

Page 5

Congratulations

Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation.

General Instructions

This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit. For years of trouble-free service, please follow the installation instructions closely. We cannot overemphasize the importance of proper installation.

WARNING

Refrigeration system under high pressure

Do not puncture, heat, expose to flame or incinerate.

Only certified refrigeration technicians should service this equipment.

R410A systems operate at higher pressures than R22 equipment. Appropriate safe service and handling practices must be used.

Only use gauge sets designed for use with R410A. Do not use standard R22 gauge sets.

Here are some suggestions to help you use your new Friedrich most efficiently:

1.Carefully read and follow the installation instructions.

2.Make sure the unit is the right capacity for the area being cooled. An undersized unit makes the unit work too hard, using more electricity than needed and increases wear. An oversized unit will cycle on and off too rapidly, and therefore cannot control humidity as well.

3.Clean the filter frequently (See Routine Maintenance, Page 27).

4.Do not block the air flow to and from the unit.

5.A dirty filter or improperly set controls can affect the cooling ability of the unit.

6.If cooling is weak and you have verified that the filter is clean

and the controls are properly set, the unit may need service and you should call your Friedrich service provider to check the unit.

7.Keep blinds, shades and drapes closed on the sunny side of the room being cooled to reduce radiant heat.

8.Proper insulation helps your unit maintain the desired inside temperature.

9.Whenever possible, shade south and west facing windows.

10.Keep window coverings away from the unit to provide free air flow.

WARNING

Read Installation Operation

Manual

Please read this manual thoroughly prior to equipment installation or operation.

It is the installer’s responsibility to properly apply and install the equipment. Installation must be in conformance with the NFPA 70 -2008 National Electric Code or current edition, International Mechanic Code 2009 or current edition and any other applicable local or national codes.

Failure to do so can result in property damage, personal injury or death.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is a safety Alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol with the word “WARNING” or “CAUTION”. These words mean:

WAR￿A￿NINING￿

CAUTION

Indicates a hazard which, if not avoided, can result in severe personal injury or death and damage to product or other property.

Indicates a hazard which, if not avoided, can result in personal injury and damage to product or other property.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what will happen if the instructions are not followed.

NOTICE

Indicates property damage can occur if instructions are not followed.

3

Image 5
Contents Ptac Page Table of Contents Page General Instructions Read Installation Operation ManualCongratulations Installation Checklist General SpecificationsTypical Building Plan View Ptac Installation RecommendationsFor Deep Wall Installation Greater than 13 1/4 See Wall Sleeve Installation Instructions PdxwsTypical Wall Sleeve Installation Falling Object HazardPanel Wall Alternate Wall InstallationsFrame and Brick Veneer Curtain WallWall Sleeve Attachment DimensionsLintel Installation One-Piece Deep Wall Sleeve Installation PdxwsextInternal Drain Drain Kit Location and InstallationDrain Kit Installation Cover Plate InstallationDrain Tube Installation See Figure Standard Grille Pxga Standard Grille Installation InstructionsElectrical Rating Tables Power Cord Information 230/208V models onlyAll 230/208 volt units are equipped with power cords Electrical Shock Hazard Electrical Wiring for 265 Volt ModelsPower Cord Installation To Chassis Junction Suffocation Hazards Chassis Install PreparationShipping Screw Location Unit Damage HazardShipping Tape Location Securing Unit Chassis InstallationExcessive Weight Hazard Power Connection How To ConnectFriedrich Ptac Digital Control and Unit Features Page System Configuration Dip Switches Digital Control User Input ConfigurationDip Switch Setting Digital Control Operation Remote Control Thermostat Installation Energy Management Desk Control TerminalsRoutine Maintenance Complaint Cause Solution Basic TroubleshootingService & Assistance New Construction Accessories AccessoriesPxcja Room AIR Conditioners Limited Warranty Page 66129906249