Friedrich 920-087-09 operation manual General Specifications, Installation Checklist

Page 6

General Specifications

Typical Unit Components and Dimensions

WALL SLEEVE

 

DISCHARGE

OUTDOOR GRILLE

 

GRILLE

 

FILTERS

PDXWS Wall Sleeve Dimensions:

 

 

16" H x 42" W x 13-¾" D

 

Front Cover Dimensions:

 

16" H x 42" W x 7-¾" D

 

Cut-Out Dimensions:

 

16-¼" x 42-¼"

RETURN AIR GRILLE

CHASSIS

 

 

FRONT COVER

MODEL NUMBER

Series

PD = Friedrich Digital PTAC

System

X = Accessory

E = Cooling with or without electric heat H = Heat Pump with Auxiliary Heat

Nominal Capacity

 

 

07 = 7,000 Btuh

12 = 12,000

Btuh

09 = 9,000 Btuh

15 = 15,000

Btuh

Voltage

K = 230/208V - 1 Ph. - 60 Hz. R = 265V - 1 Ph. - 60 Hz.

Engineering Digit

Design Series

Note: All PTAC models with a C design series or later come standard with Diamonblue seacoast protection and digital controls.

Chassis

S = Standard

Nominal Heater Size (230V or 265V)

0

= No Heater*

 

2

= 2.0 KW 3

= 3.0 KW 5 = 5.0 KW**

*No Heater only available on 230V PDE models

**5.0 kw only available on 9000, 12000 and 15000 BTU models

Installation Checklist

qInspect all components and accessories for damage before and after installation.

qRemove the cardboard wall sleeve support and grill weatherboard.

qCheck for proper wall sleeve installation in accordance with the wall sleeve installation instructions.

qCheck for a subbase kit or other means of structural support which is required for ALL installations projecting more than 8" into room.

qInstall the recommended Condensate Drain Kits for complete condensate removal.

qEnsure that the chassis is installed in a 16" high x 42” wide wall sleeve that is no deeper than 13 ¾". A baffle kit is required if the sleeve exceeds that depth.

qEnsure that chassis and chassis front cover are installed and secured properly.

qEnsure that drapes, bed, bedspread, furniture, etc. DO NOT block either return or discharge air grilles.

qInspect the condenser air inlet and outlet for any obstructions (shrubbery, etc.)

qEnsure that 'reset' button is pressed on LCD device (only on cord connected models).

4

Image 6
Contents Ptac Page Table of Contents Page Read Installation Operation Manual CongratulationsGeneral Instructions General Specifications Installation ChecklistPtac Installation Recommendations Typical Building Plan ViewTypical Wall Sleeve Installation Wall Sleeve Installation Instructions PdxwsFor Deep Wall Installation Greater than 13 1/4 See Falling Object HazardFrame and Brick Veneer Alternate Wall InstallationsPanel Wall Curtain WallDimensions Wall Sleeve AttachmentOne-Piece Deep Wall Sleeve Installation Pdxwsext Lintel InstallationDrain Kit Location and Installation Internal DrainCover Plate Installation Drain Tube Installation See FigureDrain Kit Installation Pxga Standard Grille Installation Instructions Standard GrillePower Cord Information 230/208V models only All 230/208 volt units are equipped with power cordsElectrical Rating Tables Electrical Wiring for 265 Volt Models Power Cord InstallationElectrical Shock Hazard To Chassis Junction Chassis Install Preparation Suffocation HazardsUnit Damage Hazard Shipping Tape LocationShipping Screw Location Chassis Installation Excessive Weight HazardSecuring Unit How To Connect Power ConnectionFriedrich Ptac Digital Control and Unit Features Page System Configuration Digital Control User Input Configuration Dip Switch SettingDip Switches Digital Control Operation Remote Control Thermostat Installation Desk Control Terminals Energy ManagementRoutine Maintenance Basic Troubleshooting Complaint Cause SolutionService & Assistance Accessories New Construction AccessoriesPxcja Room AIR Conditioners Limited Warranty Page 66129906249