General Specifications
Typical Unit Components and Dimensions | |
WALL SLEEVE |
|
DISCHARGE | OUTDOOR GRILLE |
| |
GRILLE |
|
FILTERS | PDXWS Wall Sleeve Dimensions: |
| |
| 16" H x 42" W x |
| Front Cover Dimensions: |
| 16" H x 42" W x |
| |
| |
RETURN AIR GRILLE | CHASSIS |
| |
| FRONT COVER |
MODEL NUMBER
Series
PD = Friedrich Digital PTAC
System
X = Accessory
E = Cooling with or without electric heat H = Heat Pump with Auxiliary Heat
Nominal Capacity |
|
|
07 = 7,000 Btuh | 12 = 12,000 | Btuh |
09 = 9,000 Btuh | 15 = 15,000 | Btuh |
Voltage
K = 230/208V - 1 Ph. - 60 Hz. R = 265V - 1 Ph. - 60 Hz.
Engineering Digit
Design Series
Note: All PTAC models with a C design series or later come standard with Diamonblue seacoast protection and digital controls.
Chassis
S = Standard
Nominal Heater Size (230V or 265V)
0 | = No Heater* |
|
2 | = 2.0 KW 3 | = 3.0 KW 5 = 5.0 KW** |
*No Heater only available on 230V PDE models
**5.0 kw only available on 9000, 12000 and 15000 BTU models
Installation Checklist
qInspect all components and accessories for damage before and after installation.
qRemove the cardboard wall sleeve support and grill weatherboard.
qCheck for proper wall sleeve installation in accordance with the wall sleeve installation instructions.
qCheck for a subbase kit or other means of structural support which is required for ALL installations projecting more than 8" into room.
qInstall the recommended Condensate Drain Kits for complete condensate removal.
qEnsure that the chassis is installed in a 16" high x 42” wide wall sleeve that is no deeper than 13 ¾". A baffle kit is required if the sleeve exceeds that depth.
qEnsure that chassis and chassis front cover are installed and secured properly.
qEnsure that drapes, bed, bedspread, furniture, etc. DO NOT block either return or discharge air grilles.
qInspect the condenser air inlet and outlet for any obstructions (shrubbery, etc.)
qEnsure that 'reset' button is pressed on LCD device (only on cord connected models).
4