Wall Sleeve Installation Instructions (PDXWS)
NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories. If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions completely before attempting installation.
WARNING
Falling Object Hazard
Not following Installation Instructions for mounting your air conditioner can result in property damage, injury, or death.
NOTICE
DO NOT allow any pitch toward the inside.
Flashing on all 4 sides of the opening is recommended.
Potential property damage can occur if instructions are not followed.
For Deep Wall Installation (Greater than 13 1/4") See Page 9
The following instructions apply ONLY to walls less than 13 ¼" in depth.
1.The PXDR10 Drain Kit (optional for new construction) see page 10 if applicable, must be installed before the wall sleeve is installed into the wall.
2.The External Drain (for new construction or unit replacement) see page 11, if applicable, must be installed before the wall sleeve is installed into the wall.
Figure 3
Typical Wall Sleeve Installation
LINTEL TO SUPPORT | |
MIN. | |
MASONRY WALLS |
|
3.From inside the building, position the wall sleeve in the opening and push it into the wall until it protrudes at least ¼” on the outside. Do not allow sleeve to be pulled. (See Figure 11, Page 10).
4.Position the wall sleeve with a slight tilt towards the outside to facilitate condensate drainage. It should be level
ELECTRICAL
RECEPTACLE
60" |
| |
| MAX. |
|
20" MAX.
13-¾"
SMOOTH SIDE OF SCREW CLIP FACING INTO ROOM
ELECTRICAL
INSULATION
RECEPTACLE
WALL OPENING
WALL SLEEVE
INSULATION
NOTE: All 230/208V units are manufactured with a 60” power cord and all 265V units with a18 ” power cord.
FRP008