Energy Tech Laboratories Modular Direct Fired Heaters manual Table of Contents

Page 2

TABLE OF CONTENTS

 

WARRANTY

3

INSTALLATION

4

Mechanical

4

Site Preparation

4

Assembly

4

Curb and Ductwork

4

Roof Mount Installation

5

Installation with Exhaust Fan

5

Direct Fired Module Installation

6

Indoor (INLINE) Installation

6

Heat Module Add-On Installation

6

Gas

7

Electrical

8

Motorized Intake Damper

8

Remote Control Panel

9

Fan to Building Wiring Connection

9

OPERATION

10

Start Up

10

Special Tools Required

10

Start Up Procedure

10

Pilot Adjustment

10

Main Burner Adjustment

11

Heater Start Up Summary

12

Final Start Up Procedure

13

Pulley Adjustment

13

Pulley Alignment

13

Proper Belt Tension

13

Pulley Combination Chart

14

Sequence of Operation

15

Flame Safety Control

15

Air Flow Switch

15

Modulating Gas System

16

High Temperature Limit

16

Operation Summary

16

Optional Remote Panel Circuit

17

Components

18

Remote Panel Option

19

Troubleshooting

20

Airflow Troubleshooting Chart

20

Burner Troubleshooting Chart

21

Remote Panel Troubleshooting Chart

22

Troubleshooting Flowcharts

23

MAINTENANCE

26

General Maintenance

26

2 weeks after startup

27

Every 3 months

27

Filter Quantity Chart

27

Yearly

27

Start-Up and Maintenance Documentation

28

Job Information

28

Heater Information

28

Maintenance Record

28

Factory Service Department

28

Image 2
Contents Installation, Operation, and Maintenance Manual Table of Contents Warranty Mechanical InstallationAssembly Site PreparationRoof Mount Installation Installation with Exhaust Fan Recommended Supply Ductwork SizesPage Gas Pressure Table GasGas Connection Sizes Motorized Intake Damper Copper Wire AmpacityElectrical Remote Control Panel Fan to Building Wiring ConnectionOperation Start UpMain Burner Adjustment Yes Adjust pilot flame Lock unit into High fire Heater Start Up SummaryPulley Adjustment Final Start Up ProcedureMaximum RPM and HP Chart Pulley Adjustment Illustration Setscrew TorquePulley Combination Chart 10 20 IN. BlowerAir Flow Switch Flame Safety ControlFlame Safety Controller DC Flame Signal Sequence of OperationOperation Summary Maxitrol Amplifier High Temperature LimitModulating Gas System Blower Switch Optional Remote Panel CircuitComponents Remote Panel Option Troubleshooting Airflow Troubleshooting ChartBurner Troubleshooting Chart Proper Spark GapRemote Panel Troubleshooting Chart Light Indication Condition Possible CauseTroubleshooting Flowcharts Nothing HappensFlame Safety Service Guide Flame Safety Service Guide Maintenance General MaintenanceEvery 3 months Filter Quantity ChartWeeks after startup YearlyFactory Service Department Start-Up and Maintenance DocumentationMaintenance Record Job Information

Modular Direct Fired Heaters specifications

Energy Tech Laboratories has established itself as a leader in the development of innovative modular direct fired heaters, designed to meet the evolving demands of industries that require efficient and effective heating solutions. These heaters are engineered to offer versatility, reliability, and enhanced performance, making them suitable for a broad range of applications.

One of the standout features of Energy Tech Laboratories' modular direct fired heaters is their modular design. This allows for easy scalability and customization, enabling users to adjust the heating capacity according to specific requirements. The modular aspect also facilitates straightforward installation and maintenance, reducing downtime and operational costs.

The heaters utilize advanced combustion technology that optimizes fuel consumption while minimizing emissions. This ensures not only a cost-effective operation but also compliance with environmental regulations. By combining high thermal efficiency with a low carbon footprint, these heaters contribute to sustainable energy practices.

In addition to their efficient combustion system, Energy Tech Laboratories incorporates state-of-the-art control technologies in their heaters. These systems allow for precise temperature regulation and can be integrated with existing Building Management Systems (BMS) for enhanced monitoring and control. Users can benefit from real-time data and analytics, which help in diagnosing potential issues and optimizing performance.

Durability is another characteristic that sets these heaters apart. Constructed with high-quality materials, they are designed to withstand harsh industrial conditions, ensuring a long service life. The robust design minimizes the likelihood of breakdowns, which is critical for industries that rely on continuous operation.

Moreover, Energy Tech Laboratories emphasizes safety in the design of their modular direct fired heaters. Equipped with multiple safety features such as flame detection, gas leak detection, and emergency shutdown systems, these heaters are built to operate within stringent safety standards.

The flexibility of these heaters makes them suitable for various sectors, including oil and gas, manufacturing, and construction. Their ability to provide direct heat quickly and efficiently makes them ideal for processes that require consistent temperature control.

In conclusion, Energy Tech Laboratories' modular direct fired heaters represent an advanced solution for today’s energy needs. With their modular design, advanced combustion technologies, and focus on safety and durability, these heaters stand out as a preferred choice for industries seeking reliable and efficient heating solutions. Their commitment to innovation and sustainability positions them as a front-runner in the energy technology sector.