This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Sears at (1-800-469-4663).

Installation Checklist

Water Heater Location

Water heater location is important and can affect system performance. Please check the following:

[] Installation area free of corrosive elements and flammable materials,

[] Centrally located with the water piping system (For new installations). Located as close to the gas piping, vent pipe system and 120VAC outlet as possible.

[] Located indoors and in a vertical position. Protected from freezing temperatures.

[] Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

[] Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

[] Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

[] Water heater not located near an air moving device.

[] Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)? If so, the air intake chamber louvers located on the side of the water heater wilt need to be cleaned periodically. Refer to the maintenance section of your water heater's manual for information on cleaning the "Air Intake Chamber Screen".

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air for the combustion of gas wilt result in a inferior burner flame "yellow- lazy", thereby allowing smoking and carbon formation (sooting) to build up in the combustion chamber.

Is the water heater installed in a closet or other small, enclosed

space?

If so:

 

[]

Are

there openings for make-up air to enter and

exit the

 

room/area?

 

[]

Are

the openings of sufficient size? Remember,

if there are

 

other gas-fired or air-consuming appliances in the same

room, you need more make-up air. Refer to the Location Requirements section of this water heater manual for specific requirements.

Fresh air not taken from areas that contain negative pressure producing devices such as exhaust fans, dryers, fireplaces, etc.

[] Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air- Conditioning & Refrigeration (HVAC-R) authorized service provider.

[] Fresh air supply free of corrosive elements and flammable vapors.

[] Ductwork is the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood. Refer to the "Checking the Draft" section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following.

[] Draft hood properly installed.

[] Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

[] Vent connector made of approved material and sized correctly.

[] Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the

"National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition.

[] Flue baffle properly positioned in the flue tube.

[] Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the "Combustion Air and Ventilation" section of this water heater manual for specific requirements.

[] Recheck for sufficient combustion air supply. Water System Piping

[] Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

[] All piping properly installed and free of leaks.

[] Heater completely filled with water.

[] Closed system pressure build-up devices installed.

[] Mixing valve (when applicable) installed per manufacturer's instructions (See Water Temperature Regulation section).

Gas Supply and Piping

[] Gas type is the same as that listed on the water heater rating plate.

[] Gas line equipped with shut-off valve, union, and drip leg.

[] Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum gases.

[] Adequate pipe size and approved pipe material.

[] An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks.

Correct any leak found.

Electrical Supply

[] Water heater to be located as close as possible to a 120VAC outlet (extension cord is not allowed).

[] Electrical supply installed according to all local and state codes or, in the absence of local and state codes, the

"National Electrical Code", ANSI/NFPS 70 current edition.

11

Image 11
Contents 317997-000 =I=€di,lldImportant Definitions Read and follow water heater warnings and instructionsExplosion Hazard Improper installation and use may result in property damageFire or Explosion Hazard Fire HazardGet to know your Water Heater InstallationClearances Accessibility High Altitude Installation Vent Connectors ChimneyPoweredAnodeRodOperation ElectricalConnections SolarInstallation WiringDiagramMaster Protection Agreements Sears Installation ServiceImportant Information About This Water Heater Excessive Weight Hazard153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 153.332620Natural 40,000 42.6 Materials Needed Pressure Relief Valve SwitchTransformer Gas Supply PipingVent Pipe System Installation ChecklistWater Heater Location Combustion Air Supply and VentilationManualgas Removing the Old Water HeaterSensor Location RequirementsSite Location Carbon Monoxide Poisoning HazardMinimum Clearance Locations High Altitude InstallationPmpey Damage Hazard Explosion Hazard Gas Pressure TestingGas Pressure Gas Requirements Gas PipingAtuml Gas Pipe Capacity Table Cue FtJHr Gas Pipe Capacity TableCarbon Monoxide Warning Unconfined SpaceConfined Space Minimum Free All Air from the BuildingLouvers and Grilles All Air from OutdoorsAll Air from Outdoors Through Ventilated Attic Draft Hood InstallationVent Pipe System Vertical Exhaust Gas Vent Vent ConnectorsVent Pipe Size Chimney ConnectionVenting Gas Vent System With Type B Double Wall Vent Pipe Piping InstallationClosed System/Thermal Expansion Pmpey Damage Hazard Temperature and Pressure Relief ValveDischarge Line Temperature Pressure Relief ValveRelief Valve and Pipe Insulation Electrical Connections Solar InstallationReplace view port if glass is missing Or damaged Manual before changing temperatureOperating Instructions Failure to do so can result in death Explosion or fireDo not touch vent Doing so can result in burns Water Heater OperationChecking the Draft Burn HazardRegulation Water TemperatureBurner Flames Emergency Shut DownHotter J Powered Anode OperationPowered Anode System Draining and Flushing Temperature and Pressure Relief Valve Explosion HarzardRoutine Preventive Maintenance Replacing the Flame Sense/Hot Surface igniter Assembly Replacement PartsRemoving the Burner from the Manifold/ Burner Assembly Removing the Manifold/Burner AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyReplacing the Gas Valve Removing and Replacing the Gas Control Valve/ThermostatDoor Gasket Burner ISlot Viewport Start Up Conditions AIR In Hot Water Faucets Safety Shut-off and Thermal SwitchCondensation Smoke OdorLeakage Checkpoints Possible Causes Pressurized Combustion Chamber System Operational ChecklistCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES 153.332620 153.332640 Pressurized Combustion ChamberKey Parts Description Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.