may satisfy your normal hot water needs. If hot water use is expected to be more than normal, a higher thermostat setting may

be required to meet the increased demand. When leaving your home for extended periods (vacations, etc.) Set the electronic

control display temperature "COOLER"(_)button to its lowest setting. This will maintain the water at tow temperatures with minimum energy losses and prevent the tank from freezing during cold weather.

Gas Control Valve/Thermostat Settings

-

FV#_ENSE EGO L_)_W

T,=IM_iq

 

HOTTER J_--------

_

COOLER

Electronic Control Display

FIGURE 32.

Powered Anode Operation

To protect the glass-lined water tank from corrosion through electrolysis, this water heater is equipped with a non sacrificial powered anode rod. The powered anode rod is non sacrificial and should not need to be replaced unless damaged.

If the powered anode rod has been damaged then the powered anode rod should be removed from the water heater tank and replaced. IMPORTANT: If the damaged powered anode rod has not been replaced but has been removed permanently, this will void any warranties.

3.Disconnect the electric connection by unplugging the water heater from the wall outlet.

4.Shut off the incoming water supply to the water heater and open a nearby hot water faucet to depressurize the water tank.

5.Remove the manifold cover outer door and connect a hose to the drain valve and terminate it to adequate drain or to the exterior of the building. Open the drain valve and allow at least 5 gallons of water from the tank to drain. Close drain and remove hose.

6.Unplug the electrical connection on top of the powered anode by pulling the wire connector up and off of the powered anode rod electrical connector (Figure 33).

7.Remove the powered anode rod by using a ratchet and a

1-1/16" socket turning counterclockwise (Figure 33) (Note: Figure 33 is shown exploded). If the socket used is short well you may have to remove the top male connector first before removing the powered anode rod.

8.Use Teflon @tape or an approved pipe sealant on threads of the new powered anode rod.

g.Prior to installing, it wilt be necessary to use pliers to bend up approximately 90 ° the electrical male connector on the top of the powered anode rod. The electrical connector should be bent upward in order to allow the 1-1/16" deep well socket to pass over the connector. Note: if using a short well socket the male connector must first be removed (Figure 33 is shown exploded for clarity).

10.

Place the powered anode rod in the spud (top of the tank)

 

and turn clockwise until the threads are hand tight. Using a

 

ratchet and 1-1/16" socket tighten down water tight (Torque

 

should be between 65 to 120 foot pounds).

11.

Open a nearby hot water faucet to purge air from the water

 

line. Fill water heater tank completely (Note: To assure the

 

water heater tank is full, keep the hot water faucet open for 3

 

minutes after a constant flow of water is obtained).

Powered

Anode I

Rod . _i-_

Powered Anode System

To ensure a long, trouble-free operating life, this water heater is equipped with a

powered anode system.

The powered anode rod is of a permanent design and does

not need replacing unless damaged.

12.

After turning off

the hot water faucet, check for water leaks

 

around powered

anode rod and immediately

correct

any if

 

found.

 

 

 

 

 

13.

Upon determining

there'sno water leak at the newly

installed

 

powered anode rod, reconnect the electrical plug connector

 

to the top of the anode male terminal.

 

 

14.

Plug the electric

 

transformer

in the walt outlet

and turn the

 

gas supply back on to the gas control valve/thermostat.

15.

Turn the gas control switch

to the "ON" position (located on

FIGURE 33.

NOTE: Whether re-installing or replacing the powered anode rod, check for any leaks and immediately correct if found.

To replace the powered anode rod:

Set the gas control valve/thermostat to its lowest setting by pressing the "COOLER" and "HOTTER" buttons together at the same time holding for 1 second. Then press the "COOLER" button to the lowest setting (Figure 32).

2.Turn gas control switch to the "OFF" position (located right side of the gas control valve/thermostat (Figure 28), and turn off the gas supply to the unit.

 

the side of the gas control valve/thermostat (Figure 28).

16.

To restart

the water heater, follow the directions on the

 

"Lighting and Operating Instructions" label located on

 

the front of the water heater near the gas control valve/

 

thermostat

(Figure 28).

17.

Upon verifying proper operation of the water heater, replace

 

the manifold cover outer door.

TEFLON® is a registeredtrademarkof E.l. Du PontDe NemoursandCompany

28

Image 28
Contents =I=€di,lld 317997-000Read and follow water heater warnings and instructions Important DefinitionsImproper installation and use may result in property damage Fire or Explosion HazardFire Hazard Explosion HazardInstallation Clearances Accessibility High Altitude InstallationVent Connectors Chimney Get to know your Water HeaterElectricalConnections SolarInstallation WiringDiagram PoweredAnodeRodOperationSears Installation Service Master Protection AgreementsExcessive Weight Hazard Important Information About This Water HeaterNatural 40,000 42.6 153.332620153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 Materials Needed Switch TransformerGas Supply Piping Pressure Relief ValveInstallation Checklist Water Heater LocationCombustion Air Supply and Ventilation Vent Pipe SystemRemoving the Old Water Heater ManualgasLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard SensorPmpey Damage Hazard High Altitude InstallationMinimum Clearance Locations Gas Pressure Testing Gas Pressure Gas RequirementsGas Piping Explosion HazardGas Pipe Capacity Table Atuml Gas Pipe Capacity Table Cue FtJHrConfined Space Unconfined SpaceCarbon Monoxide Warning All Air from the Building Louvers and GrillesAll Air from Outdoors Minimum FreeVent Pipe System Draft Hood InstallationAll Air from Outdoors Through Ventilated Attic Vent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Venting Gas Vent System With Type B Double Wall Vent PipeTemperature and Pressure Relief Valve Closed System/Thermal Expansion Pmpey Damage HazardRelief Valve and Pipe Insulation Temperature Pressure Relief ValveDischarge Line Solar Installation Electrical ConnectionsManual before changing temperature Operating InstructionsFailure to do so can result in death Explosion or fire Replace view port if glass is missing Or damagedWater Heater Operation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burnsWater Temperature Burner FlamesEmergency Shut Down RegulationPowered Anode System Powered Anode OperationHotter J Routine Preventive Maintenance Temperature and Pressure Relief Valve Explosion HarzardDraining and Flushing Replacement Parts Removing the Burner from the Manifold/ Burner AssemblyRemoving the Manifold/Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyDoor Gasket Burner ISlot Viewport Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Safety Shut-off and Thermal Switch CondensationSmoke Odor AIR In Hot Water FaucetsLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Possible CausesCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES Key Parts Description Pressurized Combustion Chamber153.332620 153.332640 Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.