Kenmore 153.33264 Get to know your Water Heater, Installation, 12-14, Gas, 17-20, Louvers, 19-20

Page 4

SAFE INSTALLATION,

USE AND

SERVICE

2

Important

Definitions

 

 

2

SAFETY

PRECAUTIONS

...........................................................................................................................

 

2-3

Table of Contents

 

 

 

4-5

PRODUCT

 

WARRANTY

 

 

6

CUSTOMER

 

RESPONSIBILITIES

.................................................................................................................

7

PRODUCT

 

SPECIFICATIONS

......................................................................................................................

8

MATERIALS

AND

BASIC

TOOLS

NEEDED

9

TYPICAL

 

INSTALLATION

............................................................................................................................

 

10

Get to know your Water Heater

10

IMPORTANT

 

INFORMATION

ABOUT THIS WATER HEATER

11

Installation

Checklist

 

 

11

INSTALLATION

INSTRUCTIONS

12-14

Removing

the Old Water

Heater

12

Location

Requirements

 

 

13

Site Location

 

 

 

 

13

Clearances

and Accessibility

..................................................................................................................................

14

High

Altitude Installation

.........................................................................................................................................

 

14

GAS SUPPLY

...............................................................................................................................................

 

 

 

 

15

Gas

Requirements

..................................................................................................................................................

 

 

15

Gas

Piping

..............................................................................................................................................................

 

 

 

 

15

Gas

Pressure

 

 

 

 

15

Gas

Pressure Testing

 

 

15

COMBUSTION

AIR

SUPPLY

& VENTILATION

17-20

Unconfined

Space

...................................................................................................................................................

 

 

17

Confined

Space

......................................................................................................................................................

 

 

 

17

All Air from

Inside

the Building

17

All Air from

Outdoors

 

 

18

Louvers

and Grilles

 

 

18

Vent Pipe System

...................................................................................................................................................

 

 

19

Draft

Hood

Installation

 

 

19-20

Vent Pipe Size

 

 

 

 

20

Vent Connectors

.....................................................................................................................................................

 

 

 

20

Chimney

Connection

 

 

20

Vertical

Exhaust

Gas Vent

 

20

WATER

SYSTEM

PIPING

.......................................................................................................................

 

21-22

Piping

Installation

 

 

 

21

Closed

System/Thermal

Expansion

22

Temperature and Pressure

Relief

Valve

22

T&P Relief Valve and Pipe Insulation

23

Image 4
Contents =I=€di,lld 317997-000Read and follow water heater warnings and instructions Important DefinitionsImproper installation and use may result in property damage Fire or Explosion HazardFire Hazard Explosion HazardInstallation Clearances Accessibility High Altitude InstallationVent Connectors Chimney Get to know your Water HeaterElectricalConnections SolarInstallation WiringDiagram PoweredAnodeRodOperationSears Installation Service Master Protection AgreementsExcessive Weight Hazard Important Information About This Water HeaterNatural 40,000 42.6 153.332620153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 Materials Needed Switch TransformerGas Supply Piping Pressure Relief ValveInstallation Checklist Water Heater LocationCombustion Air Supply and Ventilation Vent Pipe SystemRemoving the Old Water Heater ManualgasLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard SensorPmpey Damage Hazard High Altitude InstallationMinimum Clearance Locations Gas Pressure Testing Gas Pressure Gas RequirementsGas Piping Explosion HazardGas Pipe Capacity Table Atuml Gas Pipe Capacity Table Cue FtJHrConfined Space Unconfined SpaceCarbon Monoxide Warning All Air from the Building Louvers and GrillesAll Air from Outdoors Minimum FreeVent Pipe System Draft Hood InstallationAll Air from Outdoors Through Ventilated Attic Vent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Venting Gas Vent System With Type B Double Wall Vent PipeTemperature and Pressure Relief Valve Closed System/Thermal Expansion Pmpey Damage HazardRelief Valve and Pipe Insulation Temperature Pressure Relief ValveDischarge Line Solar Installation Electrical ConnectionsManual before changing temperature Operating InstructionsFailure to do so can result in death Explosion or fire Replace view port if glass is missing Or damagedWater Heater Operation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burnsWater Temperature Burner FlamesEmergency Shut Down RegulationPowered Anode System Powered Anode OperationHotter J Routine Preventive Maintenance Temperature and Pressure Relief Valve Explosion HarzardDraining and Flushing Replacement Parts Removing the Burner from the Manifold/ Burner AssemblyRemoving the Manifold/Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyDoor Gasket Burner ISlot Viewport Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Safety Shut-off and Thermal Switch CondensationSmoke Odor AIR In Hot Water FaucetsLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Possible CausesCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES Key Parts Description Pressurized Combustion Chamber153.332620 153.332640 Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.