Kenmore 153.33264, 153.33262 manual Atuml Gas Pipe Capacity Table Cue FtJHr

Page 16

Gas Pipe Capacity Table

Explosion Hazard

Explosion Hazard

Use a new CSA approved gas supply line.

Install a shut-off valve.

Do not connect a natural gas water heater to an L.P. gas supply.

Do not connect an L.P. gas water heater to a natural gas supply.

Failure to follow these instructions can result in death, explosion, or carbon monoxide poisoning.

Table 1

Gas leaks can not always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.

For more information, contact your gas supplier.

If a gas leak is detected, follow the "What to do if you smell gas" instructions on the cover of this manual.

atuml Gas Pipe Capacity Table (Cue FtJHr.)

Capacity of gas pipe of d_fferentdiameters and lengths _ncu, & _r hr,.with pr_sure drop of 0.3 in,,and s_cJf_c grayly of 0,60 (natural gas}

Nominal

iron

Pipe

 

 

Length

_

Pipe, Feet

 

 

 

 

 

 

S_....!ze,in

t__...................0 N0

30

.......................50

60

7

0 8__

0

 

 

........

17___............S2 ..............0 0

1/2

132

92

73

63

56

50

46

43

40

38

_

31

26

26

3/4

278

1_

152

i 30

i 15

i05

96

_

84,

79

72

64

59

55

1

520

:350

285

245

2!5

195

180

'170

160

150

130

12:0

110

100

1-1/4

t050

730

590

_0

440

4_

370

3_

320

_5

275

2:50

225

210

1-1/2

1600

11C(_

890

760

670

610

560

5_

490

460

,410

_0

350

32:0

AA_ the _ngth

of pipe has _en

de_ermin_

_leG

the pipe size whi,_ w_ £rovide the minimum cubic feet _r

_ur

requir_ for the gas input ra_ln_of _e water heart,

By formula:

 

 

 

 

 

 

Mi_. Cu. Ft, Per Hr, Requi,_d=

Heating Val_e of Gas (BTU/FT _}

The gas input d the water heater is maAed on the wa[e{ heater da_a p_ate,The heating vatue ef _hegas (BTU_FT_) may_ determin_ by censu_tin@the _cal #at_ra! gas ut_ityo

Table 2

LP Gas Capacity Table

Maximum _paci_ of p,i_ in _usa_s of BTU per hear of _diiuted liquefied petroleum gases (at 11 i_hes water column pressure.) Ba_ on a _ess_re drop of 0,,5inch w_er column,

No_inel

iron Pipe

 

 

 

Length

of Pi_,

Feet

 

 

 

 

 

 

........

20

3

........._

50

60

70

8_

8

_

...........125

.........50

1/2

275

189

i 52

129

114

t 03

96

8,9

83

78

69

63

3/4

576

393

315

267

237

2:17

196

185

173

162

146

132:

1

107i

732

590

5C_

448

409

378

346

322:

307

275

252:

1-1/4

2205

1496

1212

!039

913

8_

77!

724

677

630

567

511

Fxampie: input BTU _quirement of the water heater 100,000 BTUH.

To_l pipe _ength, 80 feet = 3/4" iPS required

Addit_nal tames are available in the _atest edition of _e "Na_ona! Fue_ Gas Code", ANS_ Z22& !,

16

Image 16
Contents =I=€di,lld 317997-000Read and follow water heater warnings and instructions Important DefinitionsImproper installation and use may result in property damage Fire or Explosion HazardFire Hazard Explosion HazardInstallation Clearances Accessibility High Altitude InstallationVent Connectors Chimney Get to know your Water HeaterElectricalConnections SolarInstallation WiringDiagram PoweredAnodeRodOperationSears Installation Service Master Protection AgreementsExcessive Weight Hazard Important Information About This Water HeaterNatural 40,000 42.6 153.332620153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 Materials Needed Switch TransformerGas Supply Piping Pressure Relief ValveInstallation Checklist Water Heater LocationCombustion Air Supply and Ventilation Vent Pipe SystemRemoving the Old Water Heater ManualgasLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard SensorPmpey Damage Hazard High Altitude InstallationMinimum Clearance Locations Gas Pressure Testing Gas Pressure Gas RequirementsGas Piping Explosion HazardGas Pipe Capacity Table Atuml Gas Pipe Capacity Table Cue FtJHrConfined Space Unconfined SpaceCarbon Monoxide Warning All Air from the Building Louvers and GrillesAll Air from Outdoors Minimum FreeVent Pipe System Draft Hood InstallationAll Air from Outdoors Through Ventilated Attic Vent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Venting Gas Vent System With Type B Double Wall Vent PipeTemperature and Pressure Relief Valve Closed System/Thermal Expansion Pmpey Damage HazardRelief Valve and Pipe Insulation Temperature Pressure Relief ValveDischarge Line Solar Installation Electrical ConnectionsManual before changing temperature Operating InstructionsFailure to do so can result in death Explosion or fire Replace view port if glass is missing Or damagedWater Heater Operation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burnsWater Temperature Burner FlamesEmergency Shut Down RegulationPowered Anode System Powered Anode OperationHotter J Routine Preventive Maintenance Temperature and Pressure Relief Valve Explosion HarzardDraining and Flushing Replacement Parts Removing the Burner from the Manifold/ Burner AssemblyRemoving the Manifold/Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyDoor Gasket Burner ISlot Viewport Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Safety Shut-off and Thermal Switch CondensationSmoke Odor AIR In Hot Water FaucetsLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Possible CausesCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES Key Parts Description Pressurized Combustion Chamber153.332620 153.332640 Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.