Kenmore 153.33264 Read and follow water heater warnings and instructions, Important Definitions

Page 2

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

,_

This

is the safety alert symbol,

it is used

to alert

you to potential personal

injury hazards.

 

IObey

all safety messages that

follow this

symbol

to avoid possible injury

or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure

to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low-level exposure to some of the substances included in the Act.

IMPORTANT DEFINITIONS

• Qualified Technician: A qualified technician must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be familiar with the design features and use of flammable vapor ignition resistant water heaters, and have a thorough understanding of this instruction manual.

Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The service agency must also have a thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.

Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not store or use gasoline or other

flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

© Sears Brands Management Corporation

2

Image 2
Contents =I=€di,lld 317997-000Read and follow water heater warnings and instructions Important DefinitionsFire Hazard Improper installation and use may result in property damageFire or Explosion Hazard Explosion HazardVent Connectors Chimney InstallationClearances Accessibility High Altitude Installation Get to know your Water HeaterElectricalConnections SolarInstallation WiringDiagram PoweredAnodeRodOperationSears Installation Service Master Protection AgreementsExcessive Weight Hazard Important Information About This Water Heater153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 153.332620Natural 40,000 42.6 Materials Needed Gas Supply Piping SwitchTransformer Pressure Relief ValveCombustion Air Supply and Ventilation Installation ChecklistWater Heater Location Vent Pipe SystemRemoving the Old Water Heater ManualgasCarbon Monoxide Poisoning Hazard Location RequirementsSite Location SensorMinimum Clearance Locations High Altitude InstallationPmpey Damage Hazard Gas Piping Gas Pressure TestingGas Pressure Gas Requirements Explosion HazardGas Pipe Capacity Table Atuml Gas Pipe Capacity Table Cue FtJHrCarbon Monoxide Warning Unconfined SpaceConfined Space All Air from Outdoors All Air from the BuildingLouvers and Grilles Minimum FreeAll Air from Outdoors Through Ventilated Attic Draft Hood InstallationVent Pipe System Chimney Connection Vent ConnectorsVent Pipe Size Vertical Exhaust Gas VentPiping Installation Venting Gas Vent System With Type B Double Wall Vent PipeTemperature and Pressure Relief Valve Closed System/Thermal Expansion Pmpey Damage HazardDischarge Line Temperature Pressure Relief ValveRelief Valve and Pipe Insulation Solar Installation Electrical ConnectionsFailure to do so can result in death Explosion or fire Manual before changing temperatureOperating Instructions Replace view port if glass is missing Or damagedBurn Hazard Water Heater OperationChecking the Draft Do not touch vent Doing so can result in burnsEmergency Shut Down Water TemperatureBurner Flames RegulationHotter J Powered Anode OperationPowered Anode System Draining and Flushing Temperature and Pressure Relief Valve Explosion HarzardRoutine Preventive Maintenance Removing the Manifold/Burner Assembly Replacement PartsRemoving the Burner from the Manifold/ Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyReplacing the Gas Valve Removing and Replacing the Gas Control Valve/ThermostatDoor Gasket Burner ISlot Viewport Start Up Conditions Smoke Odor Safety Shut-off and Thermal SwitchCondensation AIR In Hot Water FaucetsLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Possible CausesCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES 153.332620 153.332640 Pressurized Combustion ChamberKey Parts Description Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.