Kenmore 153.33262, 153.33264 manual Materials Needed

Page 9

MATERIALS NEEDED

To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.

EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE

IN 2 GALLONS

(7.6 LITERS) AND

5 GALLONS (18.9 LITERS) CAPACITY THROUGH LOCAL SEARS STORE

OR SERVICE CENTER.

WATER HEATER INSTALLATION KIT

WITH FLEXIBLE CONNECTORS FOR 3/4"

(19.05 mm) COPPER PLUMBING AND FLEXIBLE GAS CONNECTOR WITH FITTINGS.

METAL DRAIN PANS AVAILABLE

IN 20" (508 mm) DIAMETER

FOR WATER HEATERS HAVING

A DIAMETER 18" (457 mm) OR LESS, 24" (610mm) DIAMETER FOR WATER HEATERS HAVING A

DIAMETER 22" (559 mm) OR LESS AND AVAILABLE IN 28" (711 mm)

DIAMETER FOR WATER HEATERS

HAVING A DIAMETER 26" (660 mm)

OR LESS.

BASIC TOOLS

You may or may not need all these tools, depending on your

type of installation. These tools can be purchased at your local Sears Store.

Pipe Wrenches (2) 14" (356 mm)

Screwdriver

Tin Snips

6'(1.82 m) Tape or Folding Ruler

Garden Hose

Drill

Pipe Dope or Teflon Tape

 

DRILL

SLOT-HEAD

SCREWDRIVER

 

 

 

 

J

TIN SNIPS

 

 

 

PHILLIPS

SCREWDRIVER

 

 

 

 

PIPE DOPE

ROLL OF TEFLON

(SQUEEZE TUBE)

TAPE

(USE ONLY ON

USE FOR WATER AND GAS

CONNECTIONS

WATER

CONNECTIONS)

 

GARDEN HOSE

6 FOOT TAPE

PIPE WRENCH

ADDITIONAL TOOLS NEEDED

WHEN SWEAT SOLDERING

Tubing Cutters or Hacksaw

Propane Torch

Soft Solder

Solder Flux

Emery Cloth

Wire Brushes

PROPANE

TUBING CUTTER

TORCH

 

ROLLOF

HACKSAW

EMERY CLOTH

3/4" (19 mm) WIRE BRUSH

 

 

 

ROLL OF LEAD-FREE

SOLDER

1/2" (13 mm) WIRE BRUSH

SOFTSOLDER

FLUX

Image 9
Contents 317997-000 =I=€di,lldImportant Definitions Read and follow water heater warnings and instructionsFire or Explosion Hazard Improper installation and use may result in property damageFire Hazard Explosion HazardClearances Accessibility High Altitude Installation InstallationVent Connectors Chimney Get to know your Water HeaterPoweredAnodeRodOperation ElectricalConnections SolarInstallation WiringDiagramMaster Protection Agreements Sears Installation ServiceImportant Information About This Water Heater Excessive Weight Hazard153.332620 Natural 40,000 42.6153.332640 189 Natural 40,000 42.6 376or4102 559 57.13 1451 Materials Needed Transformer SwitchGas Supply Piping Pressure Relief ValveWater Heater Location Installation ChecklistCombustion Air Supply and Ventilation Vent Pipe SystemManualgas Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard SensorHigh Altitude Installation Pmpey Damage HazardMinimum Clearance Locations Gas Pressure Gas Requirements Gas Pressure TestingGas Piping Explosion HazardAtuml Gas Pipe Capacity Table Cue FtJHr Gas Pipe Capacity TableUnconfined Space Confined SpaceCarbon Monoxide Warning Louvers and Grilles All Air from the BuildingAll Air from Outdoors Minimum FreeDraft Hood Installation Vent Pipe SystemAll Air from Outdoors Through Ventilated Attic Vent Pipe Size Vent ConnectorsChimney Connection Vertical Exhaust Gas VentVenting Gas Vent System With Type B Double Wall Vent Pipe Piping InstallationClosed System/Thermal Expansion Pmpey Damage Hazard Temperature and Pressure Relief ValveTemperature Pressure Relief Valve Relief Valve and Pipe InsulationDischarge Line Electrical Connections Solar InstallationOperating Instructions Manual before changing temperatureFailure to do so can result in death Explosion or fire Replace view port if glass is missing Or damagedChecking the Draft Water Heater OperationBurn Hazard Do not touch vent Doing so can result in burnsBurner Flames Water TemperatureEmergency Shut Down RegulationPowered Anode Operation Powered Anode SystemHotter J Temperature and Pressure Relief Valve Explosion Harzard Routine Preventive MaintenanceDraining and Flushing Removing the Burner from the Manifold/ Burner Assembly Replacement PartsRemoving the Manifold/Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyRemoving and Replacing the Gas Control Valve/Thermostat Door Gasket Burner ISlot ViewportReplacing the Gas Valve Start Up Conditions Condensation Safety Shut-off and Thermal SwitchSmoke Odor AIR In Hot Water FaucetsLeakage Checkpoints Possible Causes Pressurized Combustion Chamber System Operational ChecklistCorrective Action Power IGN Heating Clean SW, OPEN, and Clean Screen Flashing Open YES Pressurized Combustion Chamber Key Parts Description153.332620 153.332640 Page Managemylife
Related manuals
Manual 44 pages 10.06 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.