Envision Peripherals R-410A installation manual Fan Performance Data ECM, Setting Fan Speed ECM

Page 17

 

 

 

 

 

 

 

 

 

 

 

 

ENVISION RESIDENTIAL INSTALLATION MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Performance Data - ECM

 

 

 

 

 

 

ECM2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

MAX

 

 

 

 

 

 

AIR FLOW DIP SWITCH SETTINGS

 

 

 

 

 

 

 

 

 

ESP

1

2

3

 

4

 

5

6

7

 

8

9

10

11

12

 

 

022

 

0.50

 

400

500

 

600

 

700

800

900

 

1000

1100

1200

 

 

 

 

 

 

 

L

 

M

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

 

0.50

 

400

500

 

600

 

700

800

900

 

1000

1100

1200

 

 

 

 

 

 

 

L

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

 

0.50

650

750

850

 

1000

 

1100

1200

1300

 

1400

1500

 

 

 

 

 

 

 

 

L

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

 

0.75

800

1000

1100

 

1300

 

1500

1600

1800

 

 

 

 

 

 

 

 

w/1hp*

 

 

L

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

 

0.50

650

800

900

 

1050

 

1150

1250

1350

 

1450

1550

 

 

 

 

 

 

 

 

L

 

 

 

M

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

 

0.75

800

900

1000

 

1200

 

1400

1600

1700

 

1850

2000

2200

2300

2400

 

 

w/1hp*

 

 

L

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

 

0.50

650

800

900

 

1050

 

1150

1250

1350

 

1450

1550

 

 

 

 

 

 

 

 

 

 

L

 

 

 

M

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

 

0.75

800

900

1000

 

1200

 

1400

1600

1700

 

1850

2000

2200

2300

2400

 

 

w/1hp*

 

 

 

L

 

 

 

M

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

 

0.75

800

950

1100

 

1300

 

1500

1750

1950

 

2100

2300

 

 

 

 

 

 

 

 

L

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070

 

0.75

800

950

1100

 

1300

 

1500

1750

1950

 

2100

2300

 

 

 

 

 

 

 

 

L

 

 

 

 

M

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/30/06

 

 

Factory settings are at recommended L-M-H DIP switch locations

 

 

 

 

CFM is controlled within ±5% up to the maximum ESP

 

 

 

 

M-H settings MUST be located within boldface CFM range

 

 

 

 

Max ESP includes allowance for wet coil and standard filter

 

 

 

Lowest and Highest DIP switch settings are assumed to be L and H respectively

 

 

 

 

 

 

 

 

 

 

Dual Capacity

MODEL

MAX

 

 

 

 

 

 

AIR FLOW DIP SWITCH SETTINGS

 

 

 

 

 

 

ESP

1

2

3

 

4

 

5

6

7

8

9

10

11

12

026

0.50

 

400

500

 

600

 

700

800

900

1000

1100

1200

 

 

 

 

L

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

0.50

650

750

850

 

1000

 

1100

1200

1300

1400

1500

 

 

 

 

L

 

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

0.75

800

1000

1100

 

1300

 

1500

1600

1800

 

 

 

 

 

w/1hp*

L

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

0.50

650

800

900

 

1050

 

1150

1250

1350

1450

1550

 

 

 

 

L

 

 

 

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

0.75

800

900

1000

 

1200

 

1400

1600

1700

1850

2000

2200

2300

2400

w/1hp*

L

 

 

 

 

 

M

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

0.75

800

950

1100

 

1300

 

1500

1750

1950

2100

2300

 

 

 

 

L

 

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

072

0.75

800

950

1100

 

1300

 

1500

1750

1950

2100

2300

 

 

 

 

 

L

 

 

 

 

M

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/30/06

Factory settings are at recommended L-M-H DIP switch locations

 

 

 

 

CFM is controlled within ±5% up to the maximum ESP

 

 

M-H settings MUST be located within boldface CFM range

 

 

 

 

Max ESP includes allowance for wet coil and standard filter

SW1

Lowest and Highest DIP switch settings are assumed to be L and H respectively

 

 

 

 

 

 

 

Off

A 12-position DIP switch package on the control allows the airflow levels to be set for low, medium, and high speed when using the ECM2 blower motor. Only three of the DIP switches can be in the "on" position.

• The first "on" switch (the lowest position number) determines the low speed fan setting.

• The second "on" switch determines the medium speed fan setting.

• The third "on" switch determines the high speed fan setting.

The example to the right shows SW1 on the control board configured for the following NS042 airflow settings.

• Low Speed Fan: 900 CFM

• Medium Speed Fan: 1150 CFM

• High Speed Fan: 1450 CFM

On

1

2

3

4

5

6

7

8

9

10

11

12

Setting Fan Speed - ECM

ECM2 fan motors have a 12-speed selector dip switch on the logic board (SW1) and are factory set for optimum perfor- mance. To change speeds, select the appropriate speeds on dip switch SW1. Consult the ECM2 fan performance table below for specific airflow and switch information.

CAUTION: Disconnect all power before performing this operation.

17

Image 17
Contents Envision Residential Installation Manual Voltage Model NomenclatureTable of Contents Safety Considerations General Installation InformationInstalling Vertical Units Moving and StorageHorizontal Unit Mounting Installing Horizontal UnitsWater Piping Duct SystemWater Quality Condensate Drain Freeze ProtectionMultiple Units on One Flow Center Closed Loop Ground Source SystemsSolenoid Valve Open Loop Ground Water SystemsWater Tank Preparation Desuperheater ConnectionsDesuperheater Startup Plumbing InstallationAccessory Relay Unit Power ConnectionElectrical Connections GeneralAuxiliary Heat Ratings Pump WiringElectronic Thermostat Single speed with ECM motor Unit Electrical DataPerforming this operation Setting Fan Speed PSCFan Performance Data PSC Fan Performance Data ECM Setting Fan Speed ECMTop Air Discharge Vertical Dimensional DataTOP View Horizontal Dimensional DataLeft Return BottomflowSingle Speed Physical Data Single SpeedDual Capacity Physical Data Dual CapacityEnvision Single Speed Wiring Schematic 208-230/60/1 Wiring SchematicsEnvision Single Speed Wiring Schematic 208-230/60/1 ECM 97P774-01 6/29/06 Unit Power 208-230/60/1 Envision Dual Capacity Wiring Schematic 208-230/60/1- ECM97P774-02 6/29/06 Microprocessor Control Heat, 3rd Stage Y1,Y2,W Dual Capacity Units ECM2 Airflow Selection DIP Switches SW1Emergency Heat W only Cooling OperationComfort Alert Flash Codes Compressor Monitoring/Comfort AlertComforTalk Fault FlashThermostat Displays Description OFF Position DIP Switch SettingsStartup Steps Before Powering Unit, Check The FollowingUnit Startup PSC Operation Logic DataSingle Speed Models Unit Operating ParametersFirst Stage Operation Dual Capacity ModelsGPM Pressure DropLED Definitions and Diagnostics TroubleshootingStandard Microprocessor Controls Refrigerant SystemsReplacement Procedures Preventive MaintenanceManufactured by WFI 9000 Conservation Way Fort Wayne,