Envision Peripherals R-410A installation manual Fan Performance Data PSC, Setting Fan Speed PSC

Page 16

ENVISION RESIDENTIAL INSTALLATION MANUAL

Fan Performance Data - PSC

Standard PSC Motor

 

Fan

Blower

Motor

 

 

 

 

 

Airflow (cfm) at External Static Pressure (in. wg)

 

 

 

 

Model

Spd

Size

HP

0

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.60

0.70

0.80

0.90

1.00

 

H

 

 

1110

1095

1080

1065

1045

1020

995

970

945

915

880

810

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

022

M

9 x 7

1/5

850

845

835

825

815

805

795

775

755

735

715

-

-

-

-

-

 

L

 

 

750

745

740

735

725

715

700

685

670

650

630

-

-

-

-

-

 

H

 

 

1290

1270

1245

1220

1190

1160

1125

1090

1055

1020

985

880

760

-

-

-

030

M

9 x 7

1/3

1100

1090

1075

1060

1045

1020

995

970

940

910

875

785

625

-

-

-

 

L

 

 

910

905

900

895

885

875

865

850

835

810

780

710

560

-

-

-

 

H

 

 

1665

1640

1610

1580

1550

1515

1480

1450

1415

1315

1215

1090

980

-

-

-

036

M

9 x 7

1/2

1465

1445

1425

1400

1375

1350

1325

1260

1190

1140

1090

990

890

-

-

-

 

L

 

 

1130

1115

1100

1090

1075

1035

995

965

930

895

860

795

730

-

-

-

 

H

 

 

2010

1975

1940

1905

1870

1825

1780

1735

1690

1640

1590

1470

1210

-

-

-

042

M

10 x 10

1/2

1670

1650

1630

1610

1590

1560

1530

1495

1460

1425

1390

1190

1080

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

1220

1215

1210

1295

1200

1180

1160

1130

1100

1060

1020

930

-

-

-

-

 

H

 

 

2010

1975

1940

1905

1870

1825

1780

1735

1690

1640

1590

1470

1210

 

-

-

048

M

10 x 10

1/2

1670

1650

1630

1610

1590

1560

1530

1495

1460

1425

1390

1190

1080

-

-

-

 

L

 

 

1220

1215

1210

1295

1200

1180

1160

1130

1100

1060

1020

930

-

-

-

-

 

H

 

 

2430

2400

2365

2330

2290

2255

2215

2180

2140

2095

2045

1945

1835

1715

1510

1330

060

M

11 x 10

1

2265

2235

2205

2175

2145

2110

2070

2035

2000

1960

1915

1825

1730

1605

1440

1260

 

L

 

 

2075

2050

2020

1995

1965

1940

1915

1885

1850

1820

1785

1720

1610

1505

1335

1175

 

H

 

 

2430

2400

2365

2330

2290

2255

2215

2180

2140

2095

2045

1945

1835

1715

1510

1330

070

M

11 x 10

1

2265

2235

2205

2175

2145

2110

2070

2035

2000

1960

1915

1825

1730

1605

1440

1260

 

L

 

 

2075

2050

2020

1995

1965

1940

1915

1885

1850

1820

1785

1720

1610

1505

1335

1175

Optional High Static PSC Motor

 

Fan

Blower

Motor

 

 

 

 

 

Airflow (cfm) at External Static Pressure (in. wg)

 

 

 

 

Model

Spd

Size

HP

0

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.60

0.70

0.80

0.90

1.00

 

H

 

 

1290

1270

1245

1220

1190

1160

1125

1090

1055

1020

985

880

760

-

-

-

022

M

9 x 7

1/3

1100

1090

1075

1060

1045

1020

995

970

940

910

875

785

625

-

-

-

 

L

 

 

910

905

900

895

885

875

865

850

835

810

780

710

560

-

-

-

 

H

 

 

1365

1340

1325

1305

1280

1250

1215

1180

1140

1100

1055

960

850

-

-

-

030

M

9 x 7

1/2

1040

1040

1035

1030

1020

1005

990

970

945

915

885

810

735

-

-

-

 

L

 

 

880

880

880

880

875

870

860

840

820

800

775

730

480

-

-

-

 

H

 

 

1930

1905

1875

1840

1805

1765

1725

1680

1635

1530

1425

1270

1150

1025

-

-

036

M

9 x 7

1/2

1635

1620

1600

1580

1555

1530

1505

1465

1425

1335

1240

1135

1035

775

-

-

 

L

 

 

1230

1230

1225

1215

1200

1165

1130

1095

1060

1035

1005

935

795

675

-

-

 

H

 

 

2115

2075

2035

1980

1920

1900

1880

1840

1795

1730

1660

1390

1225

1070

-

-

042

M

10 x 10

3/4

2005

1980

1950

1910

1865

1815

1765

1725

1685

1585

1485

1315

1140

1025

-

-

 

L

 

 

1860

1835

1805

1780

1750

1715

1675

1635

1590

1540

1490

1260

1115

980

-

-

 

H

 

 

2115

2075

2035

1980

1920

1900

1880

1840

1795

1730

1660

1390

1225

1070

-

-

048

M

10 x 10

3/4

2005

1980

1950

1910

1865

1815

1765

1725

1685

1585

1485

1315

1140

1025

-

-

 

L

 

 

1860

1835

1805

1780

1750

1715

1675

1635

1590

1540

1490

1260

1115

980

-

-

Factory settings are in Bold

High-Static option not available for 060 and 070

Air flow values are with dry coil and standard filter

For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]). Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg. and 500 fpm by 0.16 in. wg.

Setting Fan Speed - PSC

 

 

R

E

 

 

 

 

I

 

 

W

 

 

 

D

 

 

CAUTION: Disconnect all power before

E

 

 

E

 

 

 

P

 

 

performing this operation.

S

 

 

N

 

 

 

A

 

 

 

F

 

 

HIGH MEDIUM LOW

PSC FAN MOTOR BODY

16

Image 16
Contents Envision Residential Installation Manual Model Nomenclature VoltageTable of Contents General Installation Information Safety ConsiderationsInstalling Vertical Units Moving and StorageInstalling Horizontal Units Horizontal Unit MountingDuct System Water PipingWater Quality Freeze Protection Condensate DrainClosed Loop Ground Source Systems Multiple Units on One Flow CenterOpen Loop Ground Water Systems Solenoid ValveDesuperheater Connections Water Tank PreparationPlumbing Installation Desuperheater StartupUnit Power Connection Accessory RelayElectrical Connections GeneralElectronic Thermostat Pump WiringAuxiliary Heat Ratings Unit Electrical Data Single speed with ECM motorFan Performance Data PSC Setting Fan Speed PSCPerforming this operation Setting Fan Speed ECM Fan Performance Data ECMVertical Dimensional Data Top Air DischargeHorizontal Dimensional Data TOP ViewBottomflow Left ReturnPhysical Data Single Speed Single SpeedPhysical Data Dual Capacity Dual CapacityWiring Schematics Envision Single Speed Wiring Schematic 208-230/60/1Envision Single Speed Wiring Schematic 208-230/60/1 ECM 97P774-01 6/29/06 Envision Dual Capacity Wiring Schematic 208-230/60/1- ECM Unit Power 208-230/60/197P774-02 6/29/06 Microprocessor Control ECM2 Airflow Selection DIP Switches SW1 Heat, 3rd Stage Y1,Y2,W Dual Capacity UnitsEmergency Heat W only Cooling OperationCompressor Monitoring/Comfort Alert Comfort Alert Flash CodesThermostat Displays Fault FlashComforTalk DIP Switch Settings Description OFF PositionUnit Startup Before Powering Unit, Check The FollowingStartup Steps Operation Logic Data PSCUnit Operating Parameters Single Speed ModelsDual Capacity Models First Stage OperationPressure Drop GPMTroubleshooting LED Definitions and DiagnosticsStandard Microprocessor Controls Refrigerant SystemsPreventive Maintenance Replacement ProceduresManufactured by WFI 9000 Conservation Way Fort Wayne,