Envision Peripherals R-410A installation manual Vertical Dimensional Data, Top Air Discharge

Page 18

ENVISION RESIDENTIAL INSTALLATION MANUAL

Vertical Dimensional Data

Top Air Discharge

LEFT RETURN

RIGHT RETURN

2ft [61cm]

Primary Service Access

Q

 

 

 

 

L

O

M

R

N

 

 

 

 

TOP

 

C

 

 

 

 

 

B

 

P O

L

N

TOP

T

T

S

S

B

Q

R

 

 

 

 

1.9in

 

 

[4.8cm]

1.9in

 

 

[4.8cm]

 

 

K J I

A

D E H F G

C

 

FRONT

 

 

 

LEFT SIDE

RIGHT SIDE

 

 

Overall Cabinet

 

 

 

Water Connections

 

Electrical Knockouts

 

Discharge Connection

 

 

Return Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical

 

 

 

 

 

 

 

 

 

 

I

J

K

 

duct flange installed (±0.10 in)

 

 

using std deluxe filter rack (±0.10 in)

 

Models

A

B

C

D

E

F

G

H

Loop

 

1/2" cond

1/2" cond

3/4" cond

L

M

N

O

P

Q

R

S

 

T

 

 

 

Width

Depth

Height*

In

Out

HWG In

HWG

Cond-

Water FPT

HWG FPT

Low

Ext Pump

Power

 

 

Supply

Supply

 

 

Return

Return

 

 

 

 

 

Out

ensate

Voltage

Supply

 

 

Width

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

022-030

in.

22.5

26.5

48.5

2.0

7.0

13.5

16.5

10.2

1" Swivel

1" Swivel

8.5

10.4

11.8

6.1

0.8

14.0

14.0

4.4

1.7

22.2

26.0

 

1.7

 

cm.

57.2

67.2

123.2

5.0

17.7

34.2

41.8

26.0

21.6

26.4

29.8

15.5

2.1

35.6

35.6

11.1

4.2

56.3

66.0

 

4.4

 

 

 

 

 

 

036-038

in.

25.6

31.6

50.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

26.0

 

1.7

 

cm.

65.0

80.2

128.0

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

66.0

 

4.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042-049

in.

25.6

31.6

54.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

30.0

 

1.7

 

cm.

65.0

80.2

138.2

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

76.2

 

4.3

 

 

 

 

 

 

060-072

in.

25.6

31.6

58.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

34.0

 

1.7

 

cm.

65.0

80.2

148.3

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

86.4

 

4.3

 

 

 

 

 

 

Condensate is 3/4" PVC female glue socket and is switchable from side to front

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev.: 07/19/06 B

Vertical unit shipped with deluxe 2" (field adjustable to 1") duct collar/filter rack extending from unit 3.25" and is suitable for duct connection.

 

 

 

 

 

 

 

 

 

 

 

Discharge flange is field installed and extends 1" [25.4 mm] from cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Decorative molding and water connections extend 1.2" [30.5mm] beyond front of cabinet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Image 18
Contents Envision Residential Installation Manual Model Nomenclature VoltageTable of Contents Installing Vertical Units General Installation InformationSafety Considerations Moving and StorageInstalling Horizontal Units Horizontal Unit MountingDuct System Water PipingWater Quality Freeze Protection Condensate DrainClosed Loop Ground Source Systems Multiple Units on One Flow CenterOpen Loop Ground Water Systems Solenoid ValveDesuperheater Connections Water Tank PreparationPlumbing Installation Desuperheater StartupElectrical Connections Unit Power ConnectionAccessory Relay GeneralPump Wiring Electronic ThermostatAuxiliary Heat Ratings Unit Electrical Data Single speed with ECM motorSetting Fan Speed PSC Fan Performance Data PSCPerforming this operation Setting Fan Speed ECM Fan Performance Data ECMVertical Dimensional Data Top Air DischargeHorizontal Dimensional Data TOP ViewBottomflow Left ReturnPhysical Data Single Speed Single SpeedPhysical Data Dual Capacity Dual CapacityWiring Schematics Envision Single Speed Wiring Schematic 208-230/60/1Envision Single Speed Wiring Schematic 208-230/60/1 ECM 97P774-01 6/29/06 Envision Dual Capacity Wiring Schematic 208-230/60/1- ECM Unit Power 208-230/60/197P774-02 6/29/06 Microprocessor Control Emergency Heat W only ECM2 Airflow Selection DIP Switches SW1Heat, 3rd Stage Y1,Y2,W Dual Capacity Units Cooling OperationCompressor Monitoring/Comfort Alert Comfort Alert Flash CodesFault Flash Thermostat DisplaysComforTalk DIP Switch Settings Description OFF PositionBefore Powering Unit, Check The Following Unit StartupStartup Steps Operation Logic Data PSCUnit Operating Parameters Single Speed ModelsDual Capacity Models First Stage OperationPressure Drop GPMStandard Microprocessor Controls TroubleshootingLED Definitions and Diagnostics Refrigerant SystemsPreventive Maintenance Replacement ProceduresManufactured by WFI 9000 Conservation Way Fort Wayne,