Envision Peripherals R-410A installation manual Bottomflow, Left Return

Page 20

ENVISION RESIDENTIAL INSTALLATION MANUAL

Vertical Dimensional Data

Bottomflow

LEFT RETURN

RIGHT RETURN

C

 

L

2ft [61cm]

 

Primary Service Access

O

 

M

B

LEFT SIDE

R

N

S S

T T

B

RIGHT SIDE

Q R

N L

O

 

 

 

1.70

 

 

 

(4.3 cm)

 

 

 

4

C

 

 

3

 

 

 

 

 

 

2

 

 

 

1

 

 

 

G

K

J

 

F

I

 

 

E

 

 

 

 

 

 

 

 

D

 

 

1.90

 

 

 

(4.7 cm)

 

Q

 

 

5

 

 

A

H

 

 

FRONT

 

P

 

 

 

 

 

 

 

 

LEFT BOTTOM DISCHARGE

 

RIGHT BOTTOM DISCHARGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOOR FOOT PRINT

 

 

FLOOR FOOT PRINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overall Cabinet

 

 

 

Water Connections

 

 

Electrical Knockouts

 

Discharge Connection

 

 

Return Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duct flange installed (±0.10 in)

 

using std delux e filter rack (±0.10 in)

Bottomflow

 

 

 

 

1

2

 

3

4

5

 

 

I

J

 

K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2" cond

1/2" cond

 

3/4" cond

 

 

 

 

 

 

 

 

 

Models

A

 

B

C

D

E

 

F

G

H

Loop

 

 

L

M

N

O

P

Q

R

S

T

 

 

 

 

 

 

 

Width

 

Depth

Height

In

Out

 

HWG In

HWG Out

Condensate

Water FPT

HWG

Low

Ex t Pump

 

Power

 

 

Supply

Supply

 

 

Return

Return

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FPT

Voltage

 

Supply

 

 

Width

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

022-030

in.

22.5

 

26.5

52.5

35.3

40.2

 

46.7

49.7

3.6

1" Swivel

1" Swiv el

41.9

43.6

 

45.1

8.6

6.0

9.3

10.5

1.0

2.2

22.2

26.0

5.6

 

cm.

57.2

 

67.3

133.4

89.7

102.1

 

118.6

126.2

9.1

106.4

110.7

 

114.6

21.8

15.2

23.6

26.7

2.5

5.6

56.4

66.0

14.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-072

in.

25.5

 

31.5

62.5

43.4

48.4

 

57.0

60.0

3.6

1" Swivel

1" Swiv el

48.9

50.8

 

52.2

9.1

4.8

13.4

13.6

1.5

1.8

28.1

34.0

5.6

 

cm.

64.8

 

80.0

158.8

110.2

122.9

 

144.8

152.4

9.1

124.2

129.0

 

132.6

23.1

12.2

34.0

34.5

3.8

4.6

71.4

86.4

14.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensate is 3/4" PVC female glue socket and is switchable from side to front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev .: 09/27/07

Vertical bottomflow unit shipped with deluxe 2" (field adjustable to 1") duct collar/filter rack extending from unit 3.25" and is suitable for duct connection.

 

 

 

 

 

 

 

 

 

 

Decorative molding and water connections extend 1.2" (30.5mm) beyond front of cabinet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Image 20
Contents Envision Residential Installation Manual Model Nomenclature VoltageTable of Contents General Installation Information Safety ConsiderationsInstalling Vertical Units Moving and StorageInstalling Horizontal Units Horizontal Unit MountingDuct System Water PipingWater Quality Freeze Protection Condensate DrainClosed Loop Ground Source Systems Multiple Units on One Flow CenterOpen Loop Ground Water Systems Solenoid ValveDesuperheater Connections Water Tank PreparationPlumbing Installation Desuperheater StartupUnit Power Connection Accessory RelayElectrical Connections GeneralAuxiliary Heat Ratings Pump WiringElectronic Thermostat Unit Electrical Data Single speed with ECM motorPerforming this operation Setting Fan Speed PSCFan Performance Data PSC Setting Fan Speed ECM Fan Performance Data ECMVertical Dimensional Data Top Air DischargeHorizontal Dimensional Data TOP ViewBottomflow Left ReturnPhysical Data Single Speed Single SpeedPhysical Data Dual Capacity Dual CapacityWiring Schematics Envision Single Speed Wiring Schematic 208-230/60/1Envision Single Speed Wiring Schematic 208-230/60/1 ECM 97P774-01 6/29/06 Envision Dual Capacity Wiring Schematic 208-230/60/1- ECM Unit Power 208-230/60/197P774-02 6/29/06 Microprocessor Control ECM2 Airflow Selection DIP Switches SW1 Heat, 3rd Stage Y1,Y2,W Dual Capacity UnitsEmergency Heat W only Cooling OperationCompressor Monitoring/Comfort Alert Comfort Alert Flash CodesComforTalk Fault FlashThermostat Displays DIP Switch Settings Description OFF PositionStartup Steps Before Powering Unit, Check The FollowingUnit Startup Operation Logic Data PSCUnit Operating Parameters Single Speed ModelsDual Capacity Models First Stage OperationPressure Drop GPMTroubleshooting LED Definitions and DiagnosticsStandard Microprocessor Controls Refrigerant SystemsPreventive Maintenance Replacement ProceduresManufactured by WFI 9000 Conservation Way Fort Wayne,