Miller Electric Millermatic 350 manual Symbol Usage, Arc Welding Hazards, Electric Shock can kill

Page 5

SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING

som _2007−04

7

Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in the text.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury. The possible hazards are shown in the adjoining symbols or ex- plained in the text.

NOTICE − Indicates statements not related to personal injury.

1-2. Arc Welding Hazards

.Indicates special instructions.

This group of symbols means Warning! Watch Out! ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym- bols and related instructions below for necessary actions to avoid the hazards.

The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5.Read and follow all Safety Standards.

Only qualified persons should install, operate, maintain, and repair this unit.

During operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also

live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DAdditional safety precautions are required when any of the follow- ing electrically hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoid- able or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order presented: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit volt- age. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground − check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conduc- tor first − double-check connections.

DKeep cords dry, free of oil and grease, and protected from hot metal and sparks.

DFrequently inspect input power cord for damage or bare wiring − replace cord immediately if damaged − bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a separate cable.

DDo not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.

DDo not touch electrode holders connected to two welding ma- chines at the same time since double open-circuit voltage will be present.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

SIGNIFICANT DC VOLTAGE exists in inverter-type welding power sources after removal of input power.

DTurn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

HOT PARTS can cause severe burns.

DDo not touch hot parts bare handed.

DAllow cooling period before working on gun or

torch.

DTo handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.

OM-1327 Page 1

Image 5
Contents Processes OM-1327Description File MIG GmawFrom Miller to You Table of Contents − Programming − Maintenance &TROUBLESHOOTINGArc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsARC Rays can burn eyes and skin Fumes and Gases can be hazardousWelding can cause fire or explosion Flying Metal or Dirt can injure eyesFire or Explosion hazard Welding Wire can cause injuryFalling Unit can cause injury Moving Parts can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information About Implanted Medical DevicesIndique des instructions spécifiques Symboles utilisésUNE Décharge Électrique peut entraîner la mort LE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LES Bouteilles peuvent exploser si elles sont endommagées LE Bruit peut endommager l’ouïeRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesserLE Soudage À L’ARC risque de provoquer des interférences Proposition californienne 65 AvertissementsLES Fils DE Soudage peuvent provoquer des blessures En ce qui concerne les implants médicaux Principales normes de sécuritéInformation EMF OM-1327 Duty Cycle And Overheating SpecificationsVolt-Ampere Curve Connecting To Weld Output TerminalsInstalling Welding Gun/Cable Holder Installing Work ClampInstalling Welding Gun Connecting Spoolmatic 15A Or 30A Gun Gun End Gun Liner Wire Outlet Guide Connecting XR Edge, XR-A Gun, XR-A Python, Or XR Aluma-ProXR Edge guns prior to serial no Be sure to trim liner to proper extension11/16 Setting Gun Polarity For Wire TypePolarity Changeover Information Rear Panel Installing Gas SupplyElectrical Service Guide Installing Wire Spool and Adjusting Hub TensionInput Voltage Min Input Conductor Size In AWGSelecting Input Voltage 200/230/460 Volt Models Only Tools Needed = GND/PE Earth Ground Selecting a Location And Connecting 3-Phase Input Power18 in 457 mm for airflow Disconnect Device Input Power Connections Selection a Location And Connecting 1-Phase Input Power=GND/PE Earth Ground L1L2Hold wire tightly to keep It from unraveling Threading Welding Wire For MIG Gun150 mm Pressure4321 Indicator ScaleFor XR-A Pistol Gun Threading Welding Wire Through XR GunsTurn welding power source Off Jog Mode MIG ModePulse Indicator Light ControlsWeld Status Pulse MIG Mode Voltage AdjustmentMIG Gun-On-Demand Pulse MIG Gun-On-DemandMillerWelds.com Weld Parameters ForWeld Weld Parameters For Pulse ModeWeld Bead Setting OM-1327 MIG Welding ModeLow Setting High Setting Pulse MIG Welding ModeTimers Crater Fill display can be turned Manual Hot Start Mode Setting Hot Start Aluminum Pulse Only ParametersTo exit this menu, press the Setup 1 button OM-1327 Rmpt − Ramp TimeSetting Crater Fill Recommended Crater Fill Parameters Recommended Crater Parameters19ga 20ga 05mm 0.9mm System Reset Motor Calibration Function Set Up Push Motor Torque SUP Or Reset rES Disconnect power Routine Maintenance= Check = Change ~ = Clean = Replace OverheatingWorking on unit Measuring Input Capacitor VoltageSignificant DC voltage can Changing Drive Roll and Wire Inlet Guide Help Displays Displays a jog wire feed speed OM-1327Help Jog XXX Wire Feed SpeedTip Save MM 350PTemperatures are within acceptable limits see -2and TroubleshootingConnect work clamp to get good metal to metal contact Unit is in an overheated condition see SectionOM-1327 − Electrical Diagram 224 242-B Circuit Diagram For 460V/575V Models 223 926-B Drive Roll And Wire Guide Kits Page Page Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s