3-2. Symbols And Definitions

.Some symbols are found only on CE products.

A

Amperes

V

Volts

 

Alternating Current

X

Duty Cycle

IP

Degree Of

Hz

Hertz

 

Program

 

Wire Feed

 

Protection

 

 

 

 

 

 

 

 

 

 

 

Jog

 

Output

 

Trigger

 

Line Connection

 

Set Up

 

Sequence

 

Trigger Hold On

 

Trigger Hold Off

 

Purge

 

Press To Set

 

Start

 

Crater

 

Time

 

Preflow Time

 

Postflow Time

 

Read Instructions

U1

Increase

I1

Primary Current

I2

Rated Current

U2

Load Voltage

 

B

 

 

 

 

 

 

Primary Voltage

A

Dual Schedule

 

 

 

 

 

 

 

 

 

 

SECTION 4 − INTRODUCTION

4-1. Specifications

Type of Input

Welding Power

Wire Feed Speed

Wire Diameter

Welding

IP

Overall

 

Circuit

Weight

Power

Source Type

Range

Range

Rating

Dimensions

Rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 Volts DC

PipePro 450 RFC with

50 To 780 ipm

.023 To 1/8 in

100 Volts,

IP 21

Length: 35 in

87 lb

10 Amperes

14-Pin And Contactor

(1.3 To 19.8 mpm)

(0.6 To 3.2 mm)

750

 

(889 mm)

(39.5 kg)

 

Control

 

 

Amperes,

 

Width: 12-1/2 in

 

 

 

 

Max Spool

100% Duty

 

 

 

 

 

 

(318 mm)

 

 

 

 

Weight: 60 lb

Cycle

 

 

 

 

 

 

Height: 14 in

 

 

 

 

(27 kg)

 

 

 

 

 

 

 

 

 

(356 mm)

 

 

 

 

 

 

 

 

 

OM-230 009 Page 12

Image 16
Contents OM-230 009F ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Page Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can cause injury Fire or Explosion hazardFalling Unit can cause injury Moving Parts can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU D’EXPLO- Sion LA Chute DE L’APPAREIL peut blesserLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-230 009 Disconnect input plug or power before working on machine − DefinitionsDrive rolls can injure fingers Keep your head out of the fumesSymbols And Definitions Specifications− Introduction Rating− Installation Typical Connection Diagram For MIG EquipmentTypical Connection Diagram For TIG Equipment Typical Connection Diagram For Stick Equipment Rear Panel Connections And Rotating Drive Assembly Pin Plug Information Pin Pin InformationInstalling And Threading Welding Wire Setting Internal DIP Switches Current Detect Override OFF Factory Default S1-1 And S1-2Right Side Motor Control Board PC1 Left Side Motor PC101 Automatic Run-In OFF S1-1 And S1-2Factory Set Default Settings For DIP Switches S1 And S4 Display Board DIP Switch SettingsTools Needed Remove wrapper DIP Switch S1 And S4 Power Switch Left/Right Select Switch− Operation Operational TermsJog/Purge Switch Front Panel ControlsSee Time secProgram Push Button Upper DisplayUpper Display Upper Display Push ButtonSetup Push Button Lower DisplayAdjust Control Welding Sequence DiagramSequence Push Button WeldAuxiliary Menus Wire Feed Speed Units When the Setup button is pressed again, the menu repeatsRange Locks Software Revision LevelRemote-14 Receptacle Information At the same time, as both− Setting Sequence Parameters − Setting Dual Schedule ParametersOptional Dual Schedule Switch Diagrams Sequence Parameters In a ProgramIndicates a com Indicates a trigger Munication error Error DiagnosticsLED3-Related Error Indications − Maintenance & Troubleshooting Routine MaintenanceDisconnect power before maintaining = Check ~ = Clean = Replace Reference EveryDisconnect power before troubleshooting TroubleshootingTrouble Remedy Material Thickness Gauge − Electrical Diagram Circuit Diagram229 867-A − Parts List 21 −2Part Description Quantity Control Box GS1,101 219 Drive Assembly, Wire Drive Assembly, Wire -1Item203 Drive Roll And Wire Guide Kits Fraction Metric Kit Roll Wire SizeRoll Drive Roll Drive KitYour distributor also gives ServiceSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s