Miller Electric PipePro Dual manual Typical Connection Diagram For Stick Equipment

Page 19

5-3. Typical Connection Diagram For Stick Equipment

. The illustration shows remote control connected through the wirefeeder. The wirefeeder is not connected to the power source output..

1

2

3

5

!Do not mount feeder on top of pow- er source.

!Do not put feeder where welding wire hits cylinder.

!Do not move or operate equipment when it could tip.

4

9

6

1Welding Power Source

2Negative (−) Weld Cable

3Positive (+) Weld Cable

4Workpiece

5Electrode Holder

8

7

804 780-A

6Hand Control

7Wire Feeder

814-Pin Feeder Control Cable

9Remote Switch To STICK/TIG

.Maximum cable length not to exceed 150 feet.

OM-230 009 Page 15

Image 19
Contents File MIG Gmaw OM-230 009FProcesses DescriptionFrom Miller to You Table of Contents Page HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killFlying Metal or Dirt can injure eyes Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionMoving Parts can cause injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryAbout Implanted Medical Devices Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationUNE Décharge Électrique peut entraîner la mort Symboles utilisésLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LA Chute DE L’APPAREIL peut blesser LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées Risque D’INCENDIE OU D’EXPLO- SionLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-230 009 Keep your head out of the fumes Disconnect input plug or power before working on machine− Definitions Drive rolls can injure fingers Rating Symbols And Definitions Specifications − IntroductionTypical Connection Diagram For MIG Equipment − InstallationTypical Connection Diagram For TIG Equipment Typical Connection Diagram For Stick Equipment Rear Panel Connections And Rotating Drive Assembly Pin Pin Information Pin Plug InformationInstalling And Threading Welding Wire Automatic Run-In OFF S1-1 And S1-2 Setting Internal DIP SwitchesCurrent Detect Override OFF Factory Default S1-1 And S1-2 Right Side Motor Control Board PC1 Left Side Motor PC101Factory Set Default Settings For DIP Switches S1 And S4 Display Board DIP Switch SettingsTools Needed Remove wrapper DIP Switch S1 And S4 Operational Terms Power SwitchLeft/Right Select Switch − OperationTime sec Jog/Purge SwitchFront Panel Controls SeeUpper Display Push Button Program Push ButtonUpper Display Upper DisplayLower Display Setup Push ButtonWeld Adjust ControlWelding Sequence Diagram Sequence Push ButtonAuxiliary Menus Software Revision Level Wire Feed Speed UnitsWhen the Setup button is pressed again, the menu repeats Range LocksAt the same time, as both Remote-14 Receptacle InformationSequence Parameters In a Program − Setting Sequence Parameters− Setting Dual Schedule Parameters Optional Dual Schedule Switch DiagramsIndicates a com Indicates a trigger Munication error Error DiagnosticsLED3-Related Error Indications = Check ~ = Clean = Replace Reference Every − Maintenance & TroubleshootingRoutine Maintenance Disconnect power before maintainingDisconnect power before troubleshooting TroubleshootingTrouble Remedy Material Thickness Gauge Circuit Diagram − Electrical Diagram229 867-A 21 −2 − Parts ListPart Description Quantity Control Box GS1,101 219 Drive Assembly, Wire -1Item Drive Assembly, Wire203 Roll Drive Kit Drive Roll And Wire Guide Kits Fraction MetricKit Roll Wire Size Roll DriveYour distributor also gives ServiceSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact