Miller Electric PipePro Dual manual Remote-14 Receptacle Information, At the same time, as both

Page 32

6-13. Remote-14 Receptacle Information

 

 

1

Remote Switch

 

 

2

Remote-14 Receptacle

 

 

If the remote switch is set to MIG,

 

 

the feeder operates normally. A re-

 

 

mote control may be left attached

 

 

while the remote switch is in the

 

 

MIG mode, as the remote has no af-

 

 

fect on the operation of the wire

 

 

feeder.

 

 

If the remote switch is set to Stick/

 

 

TIG, the feeder controls and meter

 

 

displays are disabled, allowing con-

 

 

trol from a standard remote control.

 

 

When a remote control is con-

 

 

nected to the remote-14 receptacle,

 

 

the PipePro 450 RFC will automati-

 

 

cally adjust output control in a pri-

 

 

mary/secondary configuration, but

 

 

the power source must be set for

 

 

remote operation (see the PipePro

 

 

450 RFC Owner’s Manual for infor-

 

 

mation).

 

 

In this configuration, the Amp Ad-

 

 

just control on the PipePro 450 RFC

 

 

power source becomes the prima-

 

 

ry, and sets the maximum amper-

 

 

age output of the unit. The remote

 

 

control becomes the secondary,

 

 

and provides an amperage range

 

 

adjustment of 0 to 100% of what is

 

 

set on the Amp Adjust control on the

 

 

power source.

1

2

. When in Stick/Tig mode, re-

 

 

 

 

mote program select is still

 

 

 

functional from the feeder.

 

 

!

Do not connect a Stick elec-

 

 

 

trode holder and a MIG gun

 

 

 

to the same output terminal

 

 

 

at the same time, as both

 

 

 

will be live when the contac-

tor is on. An external polar- ity reversing isolation con- trol should be used to iso- late the outputs.

804 667-B

OM-230 009 Page 28

Image 32
Contents OM-230 009F ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Page Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can cause injury Fire or Explosion hazardFalling Unit can cause injury Moving Parts can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortLE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU D’EXPLO- Sion LA Chute DE L’APPAREIL peut blesserLE Soudage À L’ARC risque de provoquer des interférences Proposition californienne 65 AvertissementsLES Fils DE Soudage peuvent provoquer des blessures En ce qui concerne les implants médicaux Principales normes de sécuritéInformation EMF OM-230 009 Disconnect input plug or power before working on machine − DefinitionsDrive rolls can injure fingers Keep your head out of the fumesSymbols And Definitions Specifications− Introduction Rating− Installation Typical Connection Diagram For MIG EquipmentTypical Connection Diagram For TIG Equipment Typical Connection Diagram For Stick Equipment Rear Panel Connections And Rotating Drive Assembly Pin Plug Information Pin Pin InformationInstalling And Threading Welding Wire Setting Internal DIP Switches Current Detect Override OFF Factory Default S1-1 And S1-2Right Side Motor Control Board PC1 Left Side Motor PC101 Automatic Run-In OFF S1-1 And S1-2Tools Needed Remove wrapper DIP Switch S1 And S4 Display Board DIP Switch SettingsFactory Set Default Settings For DIP Switches S1 And S4 Power Switch Left/Right Select Switch− Operation Operational TermsJog/Purge Switch Front Panel ControlsSee Time secProgram Push Button Upper DisplayUpper Display Upper Display Push ButtonSetup Push Button Lower Display Adjust Control Welding Sequence Diagram Sequence Push Button WeldAuxiliary Menus Wire Feed Speed Units When the Setup button is pressed again, the menu repeatsRange Locks Software Revision LevelRemote-14 Receptacle Information At the same time, as both− Setting Sequence Parameters − Setting Dual Schedule ParametersOptional Dual Schedule Switch Diagrams Sequence Parameters In a ProgramLED3-Related Error Indications DiagnosticsIndicates a com Indicates a trigger Munication error Error − Maintenance & Troubleshooting Routine MaintenanceDisconnect power before maintaining = Check ~ = Clean = Replace Reference EveryTrouble Remedy TroubleshootingDisconnect power before troubleshooting Material Thickness Gauge − Electrical Diagram Circuit Diagram229 867-A − Parts List 21 −2Part Description Quantity Control Box GS1,101 219 Drive Assembly, Wire Drive Assembly, Wire -1Item203 Drive Roll And Wire Guide Kits Fraction Metric Kit Roll Wire SizeRoll Drive Roll Drive KitSupport ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s