Miller Electric 600 X, 500D Symbols And Definitions, Some symbols are found only on CE products

Page 18

3-3. Symbols And Definitions

.Some symbols are found only on CE products.

Stop Engine

Fast (Run, Weld/

Power)

Slow (Idle)

Start Engine

 

Starting Aid

 

Battery (Engine)

 

Engine Oil

 

Engine Oil

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

Check Injectors/

 

Check Valve

 

Fuel

 

Protective Earth

 

Pump

 

Clearance

 

 

(Ground)

 

 

 

 

 

 

Positive

 

Negative

 

Certified/Trained

 

Welding Arc

 

 

 

Mechanic

 

 

 

 

 

 

 

 

A

Amperes

V

Volts

 

Panel/Local

 

Remote

 

 

 

Air Temperature Or

 

 

 

Alternating

 

Engine

 

Engine

 

Output

 

 

 

 

 

Current

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

Stick (SMAW)

 

Constant Current

 

MIG (GMAW)

 

TIG (GTAW)

 

Welding

 

(CC)

 

Welding

 

 

 

 

 

 

 

Time

h

Hours

s

Seconds

1

Single Phase

 

 

 

 

3

Three Phase

 

Read Operator’s

 

Circuit Protector

 

Do Not Switch

 

Manual

 

 

While Welding

 

 

 

 

 

 

Electrode

 

 

 

Engine-Driven,

Hz

 

 

 

Work Connection

G

Three-Phase

Hertz

 

Connection

 

3

Alternator With

 

 

 

 

 

Rectifier

 

 

X

Duty Cycle

U0

Rated No Load

U2

Conventional

n

Rated Load

Voltage (Average)

Load Voltage

Speed

 

 

 

n1

Rated Idle

n0

Rated No Load

I

Current

I2

Rated Welding

Speed

Speed

Current

 

 

Contactor On

 

 

 

 

 

 

OM-4428 Page 14

Image 18
Contents Description OM-4428215 932KProcesses File Engine DriveFrom Miller to You Table of Contents Troubleshooting Electric Shock can kill Symbol UsageArc Welding Hazards HOT Parts can cause severe burnsARC Rays can burn eyes and skin Fumes and Gases can be hazardousBuildup of GAS can injure or kill Welding can cause fire or explosionEngine Hazards Compressed Air HazardsFire or Explosion hazard Welding Wire can cause injuryHOT Parts can cause burns and injury Falling Unit can cause injuryEMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings Radiation can cause interferenceUN Choc Électrique peut tuer Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation Indique des instructions spécifiquesLE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peu DES Organes Mobiles peuvent pro voquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresRisque D’INCENDIE OU D’EXPLO- Sion LES Fils DE Soudage peuvent provoquer des blessures LE Surchauffement peut endom- mager le moteur électriqueDES Organes Mobiles peuvent provoquer des blessures ’EMPLOI Excessif peut Information EMF Proposition californienne 65 Avertissements Principales normes de sécurité En ce qui concerne les implants médicaux− Definitions − 50 h StdStd Manufacturer’s Rating Labels CC ModelsSymbols And Definitions Some symbols are found only on CE productsDimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Lifting Eye Weight RatingVolt-Ampere Curves For CC Models VoltsTIG Mode Stick ModeMIG Mode Volt-Ampere Curves For CC/CV ModelsCurve shows typical fuel use under weld or power loads Fuel ConsumptionAC Generator Power Curve Duty Cycle And Overheating100% Duty Cycle At 500 Amperes Optional Three-Phase Generator Curves 12 kVA/kW Single-Phase AC Output No Weld Load20 kVA/kW Three-Phase AC Output No Weld Load Location/Airflow Clearance − InstallationInstalling Welding Generator Grounding1Using Lifting Eye Mounting Welding Generator Installing Exhaust Pipe After installing cylinder, wait atStop engine and let cool Activating The Dry Charge Battery If Applicable Connecting The BatteryDeutz F3L912 Engine Engine Prestart ChecksDeutz F4L2011 Engine FuelStick and TIG Welding Connecting To Weld Output TerminalsCorrect Installation MIG and Fcaw Welding45 m 60 m 70 m 90 m 105 m 120 m Connecting to WeldSelecting Weld Cable Sizes Output terminalsConnecting To Remote 14 Receptacle RC14 On CC/CV Models Socket− Operating Welding Generator − CC Models Front Panel Controls For CC Models See SectionEngine Gauges And Meters Engine Starting ControlsTo Start Weld ControlsRemote Amperage Control On CC Models Optional Weld Control/Arc Condition Information LabelExample Combination Remote Amperage Control Stick Work like a Pro − Operating Welding Generator − CC/CV Models Front Panel Controls For CC/CV Models See SectionVoltage/Amperage Adjust Switch And Remote 14 Receptacle 14 AC/DC Voltmeter OptionalProcess/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsRemote Voltage/Amperage Control On CC/CV Models Optional Example Combination Remote Amperage Control TIGAt least once a month, run en − Operating Auxiliary EquipmentVolt And 240 Volt Receptacles If a SupplementaryConnections Rear Of PanelClose Are made GeneratorOptional Generator Power Receptacles Standard Models 240 V 15 a AC South African Receptacle RC1Supplementary Protector CB2 Supplementary Protector CB3 Generator Power Receptacles Export Models Generator power is not affected by weld output− Maintenance Deutz F4L2011−POWERED Units Maintenance Label Deutz F4L2011-Powered UnitsRoutine Maintenance Deutz F4L2011-Powered Units Checking Generator Brushes Servicing Air Cleaner Deutz F4L2011-Powered Units To clean air filterBlow out cleanout hole. If nothing Spark Arrestor Muffler Cleanout PlugCovering cleanout hole Reinstall cleanout plug Tools Needed 3/8Do not set engine speed higher than specified Adjusting Engine Speed Deutz F4L2011-Powered UnitsStandard Models Models With Automatic Idle OptionalTo replace primary fuel filter To change oil and filterTo drain water from fuel system To replace secondary fuel filterOverload Protection Deutz F4L2011-Powered Units When a supplementary protector− Maintenance Deutz F3L912−POWERED Units Maintenance Label Deutz F3L912-Powered UnitsRoutine Maintenance Deutz F3L912-Powered Units Checking Generator Brushes See note above before cleaning. Re Ment is not covered by the warrantyClean or replace primary element if dirty CleaningsSpark Arrestor Muffler Cleanout Plug Adjusting Engine Speed Deutz F3L912-Powered Units To change oil and filter Overload Protection Deutz F3L912-Powered Units − Troubleshooting TroubleshootingWelding − CC Models Welding − CC/CV Models Standard Generator Power Optional Three-Phase Generator Power CC/CV Models OnlyEngine − Electrical Diagrams 215 221-E OM-4428 235 275-A OM-4428 215 806-E OM-4428 235 276-A OM-4428 215 807-D OM-4428 215 808-D − RUN-IN Procedure WetstackingWelding Generator Run-In Procedure Using Load Bank Keep exhaust and pipe awayFrom flammables Just generator A/V control so Run-In Procedure Using Resistance GridSpecifications section in this ManualGrounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment Electrically Bond GeneratorUse ground device as stated in electrical codes Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Amperes x Volts = WattsIndustrial Motors Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsSingle-Phase Induction Motor Starting Requirements Power Required To Start MotorHow Much Power Can Generator Supply? KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible − Parts List CC CC Models Only CV CC/CV Models OnlyDeutz F4L2011 en Dia Part Description Quantity Dia Part Description Quantity Mkgs CC191 Control Box Assembly − CC Models PLG3 Control Box Assembly − CC/CV Models 193 SWITCH, rotary 6 position gold contacts Panel, Front w/Components − CC Models GFCI1 Temp Panel, Front w/Components − CC/CV Models Panel, Front w/Components − CC/CV Models -1ItemPC6 192 PC4, PC5 189 Hardware is common 2827602 SCREW, .312−18x .75 hexwhd.66d stl pld slffmg tap−rw 601 Main Rectifier Assembly Main Rectifier Assembly -1ItemPage Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s