7-4. Troubleshooting

 

 

 

 

Y Disconnect power before troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

Remedy

 

 

Wire feeds, shielding gas flows, but

Check cable connections. Check cables for continuity, and repair or replace cables if necessary

electrode wire is not energized.

(see Section 5-3).

 

 

Wire feeder is on, display does not light

Check and reset circuit breaker at welding power source.

up, motor does not run, gas valve and

 

welding power source contactor do not

 

pull in.

 

 

 

Electrode wire feeding stops or feeds

Check gun trigger connection. See gun Owner’s Manual.

erratically during welding.

 

Check gun trigger. See gun Owner’s Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

Readjust hub tension and drive roll pressure (see Section 5-11).

 

 

 

 

 

 

 

 

 

Change to correct size drive roll (see Section 5-7and Table 9-1).

 

 

 

 

 

 

 

 

 

Clean or replace dirty or worn drive roll.

 

 

 

 

 

 

 

 

 

Incorrect size or worn wire guides.

 

 

 

 

 

 

 

 

 

Replace contact tip or liner. See gun Owner’s Manual.

 

 

 

 

 

 

 

 

 

Remove weld spatter or foreign matter from around nozzle opening.

 

 

 

 

 

 

 

 

 

Check brushes in drive motor. If brush length is less than 1/4 inch, replace brushes.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agency check drive motor or motor control board PC1.

 

 

Motor runs slowly.

Check for correct input voltage.

 

 

Wire feeder power is on, displays light

Check welding gun trigger leads for continuity, and repair leads or replace gun.

up, feeder jogs, purges, but unit is in-

 

operative.

 

 

 

When triggered wire feeds but no gas,

If the welding arc does not establish in 3 seconds after the gun trigger is activated the unit will feed

no contactor.

wire, but turns off contactor and gas valve. If the gun trigger is still activated after two minutes, the

 

 

 

 

wire will stop feeding.

 

 

 

 

 

OM-228 322 Page 25

Image 29
Contents Processes OM-228 322ADescription File MIG GmawFrom Miller to You Table of Contents Standards Decwire6/05Directives Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéKeep your head out of the fumes Disconnect input plug or power before working on machineDrive rolls can injure fingers Rating Label For CE Products Symbols And DefinitionsWeee Label Welding Overall Maximum Wire Feed SpecificationsSite Selection RatingEquipment Connection Diagrams Left Side Shown Rear Panel Connections And Rotating Drive AssemblyTools Needed 9/16, 5/8 Connection Point a Point B Installing Drive Rolls Wire Type, Size, And Feed Speed Capability TablePin Plug Information Gun Recommendation TableInstalling PD continuous wire guides with PD drive rolls Installing PD Continuous Wire GuidesInstalling wire guides with non- PD old-style drive rolls Installing Non-PD Old Style Wire GuidesRotate guide holder 180 degrees and reinstall Tools Needed 16, 1/8, 5/32Installing gun with Accu-Mate connection Installing Welding GunSecure gun by tightening power clamp knob Installing gun without Accu- Mate connectionEnd Of Liner No Wire SlipWire Slips Run-In Disabled S1-1 Motor Board DIP Switch SettingsManually Adjusted Run-In S1-1 And S1-2 Left Side Motor Control Board PC101 Right Side MotorPC60 Display Board DIP Switch SettingsLeft/Right Select Switch Power SwitchPower Switch Jog/PurgeVoltage Control And Digital Meters Trigger Hold SwitchTrigger Hold Switches Brush Inspection And Replacement Routine MaintenanceDisconnect power before maintaining = Check ~ = Clean = Replace Reference EveryDiagnostics Trouble Remedy TroubleshootingDisconnect power before troubleshooting − Electrical Diagram 204 716-B 22 -2 Main AssemblyPart Description Quantity Control Box 130 Harness Connectors/ReceptaclesDrive Assembly, Wire -1Item Drive Assembly, Wire Left Side Drive Assembly ShownDrive Assembly With Motor Left Side Drive Assembly Shown PD-V Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s