SECTION 4 − INTRODUCTION
4-1. Specifications
Type of Input | Welding Power | Wire Feed Speed | Wire Diameter | Welding | IP | Overall |
| |
Circuit | Weight | |||||||
Power | Source Type | Range | Range | Rating | Dimensions | |||
Rating |
| |||||||
|
|
|
|
|
|
| ||
24 Volts AC | Constant Voltage (CV) | Standard: 50 To 780 | .023 To 1/8 in | 100 Volts, | IP 21 | Length: 35 in | 87 lb | |
DC With | ipm (1.3 To 19.8 mpm) | (0.6 To 3.2 mm) | 750 |
| (889 mm) | (39.5 kg) | ||
10 Amperes | Contactor Control |
|
| Amperes, |
| Width: |
| |
50/60 Hertz |
| Optional High Speed: | Max Spool | 100% Duty |
|
| ||
|
| (318 mm) |
| |||||
|
| 92 To 1435 ipm (2.3 | Weight: 60 lb | Cycle |
|
| ||
|
|
| Height: 14 in |
| ||||
|
| To 36.4 mpm) | (27 kg) |
|
|
| ||
|
|
|
|
|
| (356 mm) |
| |
|
| Optional Low Speed: |
|
|
|
|
| |
|
| 19 to 300 ipm |
|
|
|
|
| |
|
| (0.4 to 7.6 mpm) |
|
|
|
|
| |
|
|
|
|
|
|
|
|
SECTION 5 − INSTALLATION
5-1. Site Selection
! |
3 | ! |
4
Do not put feeder where welding wire hits cylinder.
Do not move or operate equipment when it could tip.
1 Wire Feeder
1
5
2 Rubber Feet
Choose slot that allows all rubber feet to sit securely on top of welding power source.
3 Wire Spool/Reels
4 Gas Cylinder w/Hose And
2Regulator (Customer Supplied)
. Shielding gas pressure not to exceed 100 PSI (689 kPa).
5 Welding Power Source
6 Running Gear
| . Factory voltage settings are V- |
| Min 10 and |
| using a power source with a dif- |
| ferent voltage range, see Sec- |
| tion |
6 | adjustments. |
|
Wire feeder shown is representative only and does not reflect actual unit.
Ref. 803 053