Miller Electric D-74DX manual Fire or Explosion hazard, Falling Unit can cause injury

Page 7

1-3. Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D Do not install or place unit on, over, or near combustible surfaces.

DDo not install unit near flammables.

DDo not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.

FALLING UNIT can cause injury.

DUse lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories.

DUse equipment of adequate capacity to lift and support unit.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

MOVING PARTS can cause injury.

D Keep away from moving parts such as fans.

D Keep all doors, panels, covers, and guards closed and securely in place.

DHave only qualified persons remove doors, panels, covers, or guards for maintenance as necessary.

DReinstall doors, panels, covers, or guards when maintenance is finished and before reconnecting input power.

READ INSTRUCTIONS.

D Read Owner’s Manual before using or servic- ing unit.

DUse only genuine replacement parts from the manufacturer.

OVERUSE can cause OVERHEATING

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

FLYING SPARKS can cause injury.

D Wear a face shield to protect eyes and face.

D Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection.

DSparks can cause fires — keep flammables away.

STATIC (ESD) can damage PC boards.

DPut on grounded wrist strap BEFORE handling

boards or parts.

D Use proper static-proof bags and boxes to store, move, or ship PC boards.

MOVING PARTS can cause injury.

DKeep away from moving parts.

DKeep away from pinch points such as drive rolls.

WELDING WIRE can cause injury.

DDo not press gun trigger until instructed to do so.

DDo not point gun toward any part of the body, other people, or any metal when threading welding wire.

H.F. RADIATION can cause interference.

DHigh-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.

DHave only qualified persons familiar with electronic equipment perform this installation.

DThe user is responsible for having a qualified electrician prompt- ly correct any interference problem resulting from the installa- tion.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

ARC WELDING can cause interference.

DElectromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots.

DBe sure all equipment in the welding area is electromagnetically compatible.

DTo reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

DLocate welding operation 100 meters from any sensitive elec- tronic equipment.

DBe sure this welding machine is installed and grounded according to this manual.

DIf interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.

OM-1500-7 Page 3

Image 7
Contents File MIG Gmaw OM-1500-7 204 129HProcesses DescriptionFrom Miller to You Table of Contents Directives Decwire6/05Standards HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killFlying Metal or Dirt can injure eyes Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionMoving Parts can cause injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryAbout Implanted Medical Devices Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationUNE Décharge Électrique peut entraîner la mort Symboles utilisésIndique des instructions spécifiques LES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LA Chute DE L’APPAREIL peut blesser LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées Risque D’INCENDIE OU D’EXPLO- SionLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-1500-7 Drive rolls can injure fingers Disconnect input plug or power before working on machineKeep your head out of the fumes Weee Label For Products Sold Within The EU Symbols And DefinitionsSome symbols are found only on CE products Rating Label For CE ProductsSite Selection SpecificationsRating Shielding gas pressure not to Equipment Connection DiagramsExceed 100 PSI 689 kPa Rear Panel Connections And Rotating Drive Assembly Gun Recommendation Table Wire Type, Size, And Feed Speed Capability TableMotor Speed Wire Type Wire Size Feed Speed Capability Pin Plug InformationMent above.Cut wire off. Close cover Installing And Threading Welding WirePosition Settings And Results For DIP Switch S1 Setting Internal DIP SwitchesDIP Switch S1 DIP Switch S4 Not For Customer Use When DIP switch positions are changed,Power Source Selection Menu Left/Right Select Switch Power SwitchOperational Terms Jog/Purge Switch Front Panel Controls Wire SpeedTime sec CE Models Program Push ButtonUpper Display Non-CE ModelsLower Display Setup Push ButtonTime Welding Sequence Diagram Adjust ControlSequence Push Button Upper Display Setup Push ButtonAuxiliary Menus Sequence Push ButtonWire Feed Speed Units Reset To Factory SettingsPower Source Selection Menu Trigger Hold SetupSoftware Revision Level Display HoldCode Sequence Parameters In a Program Optional Dual Schedule Switch DiagramsFor more information on Sequence Push Button see Section There is a two-position DIP DiagnosticsError LED3-Related Error IndicationsRoutine Maintenance Diagnostics For User Defined OptionsMonths Pull TroubleshootingDisconnect power before troubleshooting Trouble RemedyOM-1500-7 − Electrical Diagram 204 144-C − Parts List Part Description Quantity Control Box PLG117 165 Harness Connectors/ReceptaclesHardware is common Not available unless listed See -1 For Drive Roll & Wire Guide Kits21 . PC51,151 201 Roll Drive Kit Drive Roll And Wire Guide Kits Fraction MetricKit Roll Wire Size Roll DriveYour distributor also gives ServiceSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact