SECTION 7 − SETTING SEQUENCE PARAMETERS
7-1. Sequence Parameters In A Program
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Sequence |
| Parameters |
| |
|
|
|
|
|
|
|
|
|
|
| Volts | IPM |
| Seconds |
|
|
|
|
|
|
| ||||||||
| 1. | Preflow |
|
|
| |||||||||
|
|
|
|
|
|
| ||||||||
| 2. |
| X |
|
| |||||||||
|
|
|
|
|
|
| ||||||||
| 3. | Start | X | X |
| |||||||||
|
|
|
|
|
|
| ||||||||
| 4. | Weld | X | X |
| |||||||||
|
|
|
|
|
|
| ||||||||
| 5. | Crater | X | X |
| |||||||||
|
|
|
|
|
|
| ||||||||
| 6. | Burnback | X |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 7. Postflow |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| X = Setting available. |
|
|
|
|
.For more information on
Sequence Push Button see Section 6-11.
If time is set to zero in Weld sequence, welding continues until gun trigger is released.
If time is set to zero in any timed sequence except Weld, the sequence is skipped.
|
|
|
| Weld Time |
|
|
|
|
|
| Crater | Burnback | |
|
|
|
| Time | Time | |
|
|
|
|
| ||
Preflow | Start |
| Postflow | |||
| Time | Time |
| |||
|
| Time | ||||
|
|
|
|
| ||
|
|
|
|
|
| Time |
| Weld | Burnback |
| |||
Preflow | Crater | Postflow | Sequence | |||
Trigger |
|
|
| Trigger |
| End |
|
|
|
|
| ||
Pressed |
|
|
| Released |
|
|
SECTION 8 − SETTING DUAL SCHEDULE PARAMETERS
8-1. Optional Dual Schedule Switch Diagrams
| 1 |
| 2 |
1 | 1 |
| |
2 | 2 | TR | 2 |
|
|
| |
|
|
| 3 |
|
|
| B |
A | 3 | A |
|
|
|
| |
|
|
| 4 |
B | 4 |
|
|
1Maint 2P
2Maint 1P
.Will not function with trigger
hold and dual schedule. A