5-8. Setting Internal DIP Switches
1 DIP Switch S1
2 DIP Switch S4 (Not For Customer Use)
DIP switch S1 allows the user to make a num- ber of choices affecting unit operation.
w Defining Motor Speed (S1-7 & 8)
Switches 7 and 8 allow the user to define whether the motor in use is standard speed
.When DIP switch positions are changed, the
unit must be turned Off and then On again in order for the new settings to be active. DIP switches are only read on power up.
1
O | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
N |
|
|
|
|
|
|
|
|
. In the DIP switch S1 illustrations,
the elevated slider on each switch is shown in white. For example, the switches above are all in the Off position.
2
802 808
Position Settings And Results For DIP Switch S1
7 8
7 Off, 8 Off = Standard speed motor
7 8
7 On, 8 On = Low Speed Motor
7 8
7 Off, 8 On = High speed motor