Miller Electric D-74DX manual Rear Panel Connections And Rotating Drive Assembly

Page 19

5-3. Rear Panel Connections And Rotating Drive Assembly

8

2

1

5

4

4

5

114-Pin Control Cable - 10 Ft

(3.0 m)

2Shielding Gas Valve Fittings

Requires fitting with 5/8-18 right- hand threads. Connect customer- supplied gas hose.

3Weld Cable Terminal

4Jumper Weld Cable

5Weld Cable

6Drive Assembly

7Drive Assembly Rotation Knob

8Rating Label Location

To rotate the drive assembly, loos- en drive assembly rotation knob, rotate drive assembly, and tighten knob.

3

6

7

Tools Needed: 9/16, 5/8 in

3/16 in

803 067 / 802 825-A

OM-1500-7 Page 15

Image 19
Contents File MIG Gmaw OM-1500-7 204 129HProcesses DescriptionFrom Miller to You Table of Contents Directives Decwire6/05Standards HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killFlying Metal or Dirt can injure eyes Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionMoving Parts can cause injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryAbout Implanted Medical Devices Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationUNE Décharge Électrique peut entraîner la mort Symboles utilisésIndique des instructions spécifiques LES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LA Chute DE L’APPAREIL peut blesser LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées Risque D’INCENDIE OU D’EXPLO- SionLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-1500-7 Drive rolls can injure fingers Disconnect input plug or power before working on machineKeep your head out of the fumes Weee Label For Products Sold Within The EU Symbols And DefinitionsSome symbols are found only on CE products Rating Label For CE ProductsSite Selection SpecificationsRating Shielding gas pressure not to Equipment Connection DiagramsExceed 100 PSI 689 kPa Rear Panel Connections And Rotating Drive Assembly Gun Recommendation Table Wire Type, Size, And Feed Speed Capability TableMotor Speed Wire Type Wire Size Feed Speed Capability Pin Plug InformationMent above.Cut wire off. Close cover Installing And Threading Welding WirePosition Settings And Results For DIP Switch S1 Setting Internal DIP SwitchesDIP Switch S1 DIP Switch S4 Not For Customer Use When DIP switch positions are changed,Power Source Selection Menu Left/Right Select Switch Power SwitchOperational Terms Jog/Purge Switch Front Panel Controls Wire SpeedTime sec CE Models Program Push ButtonUpper Display Non-CE ModelsLower Display Setup Push ButtonTime Welding Sequence Diagram Adjust ControlSequence Push Button Upper Display Setup Push ButtonAuxiliary Menus Sequence Push ButtonWire Feed Speed Units Reset To Factory SettingsPower Source Selection Menu Trigger Hold SetupSoftware Revision Level Display HoldCode Sequence Parameters In a Program Optional Dual Schedule Switch DiagramsFor more information on Sequence Push Button see Section There is a two-position DIP DiagnosticsError LED3-Related Error IndicationsRoutine Maintenance Diagnostics For User Defined OptionsMonths Pull TroubleshootingDisconnect power before troubleshooting Trouble RemedyOM-1500-7 − Electrical Diagram 204 144-C − Parts List Part Description Quantity Control Box PLG117 165 Harness Connectors/ReceptaclesHardware is common Not available unless listed See -1 For Drive Roll & Wire Guide Kits21 . PC51,151 201 Roll Drive Kit Drive Roll And Wire Guide Kits Fraction MetricKit Roll Wire Size Roll DriveYour distributor also gives ServiceSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact