Saving and Restoring Configuration Parameters
11.2. Restoring Saved Parameters
This section describes the procedure for using your terminal emulation program to send saved parameters to the RSM.
1.Start your terminal emulation program and access the RSM’s Text Interface command mode using an account and port that permit Supervisor commands.
2.Configure your terminal emulation program to upload an ASCII text file.
3.Upload the ASCII text file with the saved RSM parameters. If necessary, key in the file name and directory path.
4.Your terminal emulation program will send the ASCII text file to the RSM. When the terminal program is finished with the upload, make certain to terminate the Upload mode.
Note: If the RSM detects an error in the file, it will respond with the "Invalid Parameter" message. If an error message is received, carefully check the contents of the parameters file, correct the problem, and then repeat the Upload procedure.
5.If the parameter upload is successful, the RSM will send a confirmation message, and then return to the command prompt. Type /S and press [Enter], the Status Screen will be displayed. Check the Status Screen to make certain the unit has been configured with the saved parameters.