Automatic Release - Out Of Cell Calls | |
|
|
A-131 Automatic Release - Out Of Cell Calls
General Description
When the Dterm PS series user engaged in a call moves out of the service area or enters radio zone where all the channels of ZTs are busy and the communication becomes unavailable, the call will be disconnected automatically and Reorder Tone or Out of Area Announcement will be sent to the opposite end.
Operating Procedure
No manual operation is required. When the number of the party engaged in the call is displayed, it will be cleared.
Service Conditions
1.When the electric field strength becomes weak due to the Dterm PS user moving out of the service area or entering a radio zone where all the channels of ZTs are busy, or when the Error rate exceeds the threshold, OUT OF CELL INDICATION is activated.
2.When the electric field strength becomes so weak that communication is no longer available or when Error rate exceeds the threshold, the call will be disconnected automatically.