FieldServer 1.1 user manual Parameter Description

Page 18

Ruinet Utility User Manual

 

 

Page 18 of 46

 

 

 

 

 

Parameter

Description

 

Connection

The current connection being displayed out of the total number

 

TX bytes

Number of bytes sent.

 

TX packets

Number of packets sent.

 

TX dropped

Number of packets not sent for reasons that include the transmit buffers

 

being full.

 

 

 

TX errors

Errors during transmission such as hardware errors.

 

RX IP fragments

The number of IP fragmented packets received.

 

Collisions

Number of collisions - the network is too busy.

 

TX abort errors

 

 

 

TX carrier errors

The NIC layer reports this error. Should be zero.

 

TX heartbeat errors

 

 

 

 

TX window errors

 

 

 

Max TX buffers used

The highest value for the used transmit buffer count since the

 

FieldServer was restarted. An extremely busy network may have a max

 

 

of 7 or 8 but values this high are generally not expected.

 

Tx buffers in use

Current transmit buffers in use.

 

Tx broadcast

The number of broadcast messages sent.

 

RX bytes

Number of bytes received by the API.

 

RX pkts total

Number of packets received by the API.

 

RX pkts for us

The number of received packets destined for transmission.

 

RX pkts NOT for us

The number of received packets destined for transmission not meant for

 

the API.

 

 

 

RX dropped

The number of received packets which were dropped for reasons such

 

as the Ethernet queue being full.

 

 

 

RX errors

 

 

 

RX length errors

 

 

 

RX overflow errors

 

 

 

RX crc errors

The NIC layer reports this error. Should be zero.

 

RX frame errors

 

 

 

 

RX frame errors

 

 

 

RX buffer full

 

 

 

RX ring buffer error

 

 

 

RX IP type

Number of messages using IP protocol received.

 

RX ARP type

Number of messages using ARP protocol received.

 

RX BACNET type

Number of messages using BACnet protocol received.

 

RX 802_3 type

Number of messages using 802_3 Ethernet protocol received.

 

RX UNKNOWN type

Number of messages using other Ethernet protocol received.

 

Frag buf overrun

IP defrag on the receive side. The buffer is (about 80kb) is full.

 

RX Broadcast

Number of packets received in broadcast.

 

Exception 1

The Ethernet packet type could not be identified

 

 

An Ethernet packet received (i.e. addressed to the FieldServer Ethernet

 

Exception 2

address) was addressed to another IP address - either an Ethernet

 

broadcast was sent with a specific IP address, or another device has an

 

 

 

 

incorrect ARP table.

 

Exception 3

A UDP packet of length >1500 was received which cannot be handled

 

by the FieldServer.

 

 

 

Exception 4

The Ethernet TX interrupt handler was kick started.

 

RX global timeout

This statisticis currently not used.

 

RX local timeout

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 18
Contents Ruinet Version RevTable of Contents Appendix C Advanced Topics PC Requirements Hardware Installation and SetupGeneral Overview SoftwareRemote User Interface RuiNet Connecting to a FieldServer FieldServer Information Settings Aspect FieldServer InformationFieldServer Information Settings Aspect Parameter DescriptionFieldServer Information Status Aspect Connection Overview Connection Overview ScreenConnection Overview Settings aspect Connection Overview Settings Aspect Reference source not found. for further informationConnection Overview Status Aspect Connection Overview Statistics Aspect Descriptor. See Error! Reference source not found Parameter Description Connection Overview Error Statistics Aspect NAKConnection Overview API Aspect Parameter Description Node Overview Node Overview ScreenNode Overview Settings Aspect Node Overview Status Aspect Node Overview Operating Statistics AspectParameter Description Node Overview Error Statistics Aspect Map Descriptor Overview Map Descriptor Overview ScreenMap Descriptor Overview Settings Aspect Map Descriptor Overview Status AspectMap Descriptor Overview Operating Statistics Aspect Map Descriptor Overview Error Statistics Aspect Data Array Overview Data Array Detail ScreenError Messages Driver MessagesDownload Configuration to FieldServer Procedure for Downloading a File from a PC to a FieldServerUpload Configuration from FieldServer Procedure to Upload a File from a FieldServer to a PCProcedure to Change a FieldServer’s IP Address Obtain the IP address using the Dhcp ClientChange IP Address Obtain the IP address using the FieldServer’s Dhcp Server Change UI Display Mode Restart FieldServerPage Appendix A.2. File Download Appendix B.5. Disable Auto Connect Mode -m0 Appendix B.2. Connecting to a FieldServer using Name -yAppendix B.3. Broadcast Mode -ib Appendix B.4. The Most Recently Connected FieldServer -pAppendix B.6. Restart a FieldServer -b Appendix B.7. Startup ScreenAppendix B.8. Transferring files -l, -f Appendix B.9. Downloading Files -u0 Appendix B.10. Uploading Files -u1Appendix B.11. Forcing a Download -o Appendix B.12. Number of File Transfer Tries -nAppendix B.14. Set Local File Name for a Transfer -l Appendix B.17. Version Information -v, -ve Appendix B.15. Help -hAppendix B.16. Create a Log File -a Appendix B.18. Skip date and time check on connect -m1Appendix B.21. Set Timeout -k Appendix B.22. Run in Test ModeAppendix B.19. Delete a File -z Appendix C.2. FieldServer Tiers Appendix C.3. Connecting to a FieldServer over the Internet Diagram below shows how this is typically doneAppendix D. Default settings for parameters Parameter Default Setting