FIG. 12 Table Top Cable - Specification Elements

Touch Panel Accessories

DESCRIPTION:

9/PAIRS COMPOSITE CABLE CONSISTING OF: ELEMENT #1:

 

TWO 4/PAIR 24 AWG STRANDED TINNED COPPER,

 

POLYETHYLENE INSULATION, ELEMENT #2: 1/PAIR 18 AWG

 

STRANDED TNNED COPPER, PVC INSULATION AND FOIL

 

SHIELDED OVERALL PAPER BINDER AND FLEX-PVC JACKET.

ELEMENT #1:

2 X 4/PAIRS:

24 AWG STRANDED COPPER

CONDUCTOR:

24 AWG 7/32 TINNED COPPER; OD .024" NOMINAL

INSULATION:

.0075" WALL POLYETHYLENE; OD .039" NOMINAL

COLOR CODE:

P1: WHITE/BLUE, BLUE

 

P2: WHITE/ORANGE, ORANGE

 

P3: WHITE/GREEN, GREEN

PAIR:

P4: WHITE/BROWN, BROWN

2 CONDUCTORS TWINNED LEFT HAND LAY

CABLE:

(TWISTED AT VARIED LAYS TO MINIMIZE CROSS TALK)

4/P CABLED LEFT HAND LAY (BLUE BINDER, ORANGE BINDER)

BINDER:

PAPER TAPE

 

ELEMENT #2:

1 PAIR: 18 AWG SHIELDED

CONDUCTOR: 18 AWG 16/30 TINNED COPPER; OD .046" NOMINAL

INSULATION:

.010" WALL PVC; OD .066" NOMINAL

COLOR CODE:

BLACK, RED

 

DRAIN WIRE:

#22 7/30 TINNED COPPER

SHIELD:

ALUM/POLYESTER TAPE (FOIL SIDE IN)

FINAL ASSEMBLY:

TWO ELEMENT #1 & ELEMENT #2 CABLED ON COMMON

 

AXIS TO MINIMIZE DIAMETER

BINDER:

CLOTH TAPE 25% OVERLAP

JACKET:

.045" WALL FLEXIBLE PVC,

COLOR:

BLACK MATT

 

DIAMETER:

.375 INCHES NOMINAL

MARKING:

NONE

 

FIG. 12 Table Top Cable - Specification Elements

Each bundle of 4 twisted pairs includes a colored tape indicator for identification.

Installing CAT5 Suppression Ferrites

Before connecting the RJ-45 cables to the panel, install the necessary number of CAT5 Suppression Ferrites (FIG. 13) to their appropriate locations. These ferrites come as part of the Installation Kits mentioned in the previous Specification table (page 2). No tools are required for this installation.

Release the latch to

Insert the CAT5

Push down on the

open the plastic

cable and close

enclosure until it

enclosure.

the enclosure.

snaps closed.

 

FIG. 13 Installing the CAT5 Suppression Ferrites

All 1200V-Series, VG-Series, and Table Top CV10 panels require the installation of an appropriate number of CAT5 Suppression Ferrites when they use an RJ-45 cable to feed an A/V signal from the breakout box.

1.The CAT5 Suppression Ferrite is housed within a plastic enclosure (shown in FIG. 12) with a latch release on one side. Pull to release the latch and open the enclosure.