AMX NXT-1200V manual Configuring Communication, Modero Setup and System Connection

Models: NXT-1200V

1 196
Download 196 pages 6.82 Kb
Page 61
Image 61
Configuring Communication

Configuring Communication

Configuring Communication

Communication between the Modero panel and the Master is done using either USB or ETHERNET (DHCP or Static IP). Ethernet communication can be achieved through either a direct connection (Ethernet) or through the use of the optional NXA-PCI80211G wireless interface card.

USB input devices must be plugged into the rear or side USB connectors before the G4 panel is powered-up. The panel will not detect a USB connection of this type until after the unit cycles power.

Before commencing, verify you are using the latest NetLinx Master and Modero panel firmware. Verify you are using the latest versions of AMX’s NetLinx Studio and TPDesign4 programs.

Modero Setup and System Connection

1.Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 50).

Modero Setup and System Connection Connection Status

Red Connection Status icon - indicates no connection to a Master

Green Connection Status icon - indicates communication to a Master

Yellow Connection Status icon -

indicates an unreliable network connection

Battery Base button doesn’t appear until NXT is connected to a BASE/B

FIG. 50 Setup page

2.Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and display an on-screen keypad.

3.Enter 1988 into the Keypad’s password field and press Done when finished.

Clearing Password #5, from the initial Password Setup page, removes the need for you to enter the default password before accessing the Protected Setup page.

4.Press the red Device Number field to open the Device Number keypad (FIG. 51).

5.Enter a Device Number value for the panel into the Device Number Keypad. The default is 10001 and the range is from 1 - 32000.

When using multiple panels within a NetLinx System, remember to assign unique

Device Number values to each panel so that all assigned panels appear in the

System listing for the target Master.

6.Press Done to close the keypad, assign the number, and return to the Protected Setup page.

1200V Modero Video Touch Panels

51

 

 

Page 61
Image 61
AMX NXT-1200V manual Configuring Communication, Modero Setup and System Connection