Programming

"^" Button Commands (Cont.)

^BOR

Refer to theTPD4 Border Styles by Name table on page 130 for more

Set a border to a

information.

 

specific border

Syntax:

style associated

"'^BOR-<vt addr range>,<border style name or border value>'"

with a border

Variable:

value for those

 

buttons with a

variable text address range = 1 - 4000.

defined address

border style name = Refer to theTPD4 Border Styles by Name table on page 130.

range.

border value = 0 - 41.

 

 

Examples:

 

SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"

 

Sets the border by number (#10) to those buttons with the variable text range of 500-504

 

& 510-515.

 

SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"

 

Sets the border by name (AMX Elite) to those buttons with the variable text range of

 

500-504 & 510-515.

 

The border style is available through the TPDesign4 border-style drop-down list. Refer to

 

theTPD4 Border Styles by Name table on page 130 for more information.

 

 

^BOS

The new Slot ID # is set only if the specified slot is not the same as the current slot

Set the video

selected. Passthru sets the passthru mode to On.

This is an optional parameter and ONLY passes data to the PC.

window slot ID #

 

to the new Slot

Syntax:

ID #.

"'^BOS-<vt addr range>,<button states range>,<slot

 

 

number>,<passthru>'"

 

Variable:

 

variable text address range = 1 - 4000.

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

slot number = 0 = No Video Fill (Video Off)

 

1 = Composite Video (Video Fill) (Video On)

 

2 = Component RGB

 

3 = Streaming Video. 1200V panels only have Slot 1 available.

 

passthru = Passthru disable = 0 or Passthru enable = 2.

 

Example:

 

SEND_COMMAND Panel,"'^BOS-500,1,1'"

 

Sets the button to display Composite video with no pass-thru.

 

Refer to theVideo Adjustment Slide-Out Option Bar section on page 101 for more informa-

 

tion on the slot assignments within a panel.

 

 

^BPP

Zero clears the flag.

Set or clear the

Syntax:

protected page flip

"'^BPP-<vt addr range>,<protected page flip flag value>'"

flag of a

Variable:

button.

 

 

variable text address range = 1 - 4000.

 

protected page flip flag value range = 0 - 4 (0 clears the flag).

 

Example:

 

SEND_COMMAND Panel,"'^BPP-500,1'"

 

Sets the button to protected page flip flag 1 (sets it to password 1).

 

 

142

1200V Modero Video Touch Panels

Page 152
Image 152