AMX NXT-1200V manual Confirm and View the current AMX USB device connections, Before beginning

Models: NXT-1200V

1 196
Download 196 pages 6.82 Kb
Page 66
Image 66
Step 3: Confirm and View the current AMX USB device connections

Configuring Communication

Step 3: Confirm and View the current AMX USB device connections

1.Navigate to Start > Settings > Control Panel > and double-click the System icon to launch the System Properties dialog.

2.Select the Hardware tab and click on the Device Manager button to launch the Device Manager dialog.

Within the Device Manager dialog, the AMX USBLAN device appears under Network Adapters (FIG. 55) and has a unique name such as AMX USB LAN LINK #2. The number changes depending on which recognized panel is currently connected.

USB connected touch panel (showing the recognized panel)

FIG. 55 Device Manager dialog showing USB device

To remove the USB driver association from a previously connected touch panel, you must navigate back to the Device Manager, right-click on the panel’s USB driver (example AMX USB LAN LINK #2) and select Uninstall from the context menu and then OK.

Once the system completes the removal of the device, the Device Manager window will refresh, and the device will no longer appear.

The next time this device is connected to the computer it will appear as a new hardware device and will need to be associated again with the driver (refer to Step 2: Confirming the Installation of the USB Driver on the PC section on page 54.

Step 4: Using a USB to Configure a Virtual Master (using NetLinx Studio)

When configuring your panel to communicate via USB with a Virtual Master (on your PC), ONLY the USB connection option must be selected within the Type field. Since this is a direct connection, the PC’s IP Address is not needed.

Before beginning:

1.Verify the panel has been configured to communicate via USB within the System Settings page and that the USB driver has been properly configured. Refer to the previous section for more information.

2.Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx Studio 2 > NetLinx Studio 2).

3.Select Settings > Master Communication Settings, from the Main menu to open the Master Communication Settings dialog (FIG. 56).

4.Click the Communications Settings button to open the Communications Settings dialog.

56

1200V Modero Video Touch Panels

Page 66
Image 66
AMX NXT-1200V manual Confirm and View the current AMX USB device connections, Before beginning