Installing an NXD into an (optional) Rack Mount Kit (NXA-RK12)

Installation Procedures: NXD-1200V Panels

10.Place the magnetic faceplate (A in FIG. 41) back onto the main NXD unit (B in FIG. 41). Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front bezel/faceplate.

11.Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective locations on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.

12.Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing an NXD into an (optional) Rack Mount Kit (NXA-RK12)

1.Remove the magnetic faceplate/bezel from the main NXD unit by gripping the faceplate and pulling with gentle outward force.

2.Thread the incoming RJ-45, Ethernet, USB, and any optional audio/video wiring through the opening in the equipment rack (from their terminal locations). Refer to the Wiring Guidelines for the 1200V Panels section on page 45 for pinout descriptions. Leave enough slack to accommodate any re-positioning of the panel.

3.Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch panel.

Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power connector.

The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.

4.Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify the panel is receiving power and functioning properly to prevent repetition of the installation.

5.Disconnect the terminal end of the power cable from the connected power supply.

Don’t disconnect the connectors from the touch panel. The unit must be installed with the necessary connectors before being inserted into the equipment rack.

6.Insert the main 12-inch Modero unit into an NXA-RK12 (FIG. 42).

Rack mount

 

Faceplate

 

frame (NXA-RK12)

FIG. 42 NXD-1200V 12 inch Wall Mount panel installed into an NXA-RK12 Rack Mount Kit

44

1200V Modero Video Touch Panels

Page 54
Image 54