AMX NXT-1200V Page Commands Cont, Programming, Ppof, Ppog, Ppon, 1200V Modero Video Touch Panels

Models: NXT-1200V

1 196
Download 196 pages 6.82 Kb
Page 136
Image 136
PPOF

Programming

Page Commands (Cont.)

PPOF

If the page name is empty, the current page is used (see example 2). If the popup page is

Deactivate a

part of a group, the whole group is deactivated. This command works in the same way as

the ’Hide Popup’ command in TPDesign4.

specific popup

 

page on either a

Syntax:

specified page or

"'PPOF-<popup page name>;<page name>'"

the current page.

Variable:

 

 

popup page name = 1 - 50 ASCII characters. Name of the popup page.

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'PPOF-Popup1;Main'"

 

Deactivates the popup page ’Popup1’ on the Main page.

 

Example 2:

 

SEND_COMMAND Panel,"'PPOF-Popup1'"

 

Deactivates the popup page ’Popup1’ on the current page.

 

 

PPOG

If the page name is empty, the current page is used (see example 2). Toggling refers to the

Toggle a specific

activating/deactivating (On/Off) of a popup page. This command works in the same way

as the ’Toggle Popup’ command in TPDesign4.

popup page on

 

either a specified

Syntax:

page or the

"'PPOG-<popup page name>;<page name>'"

current page.

Variable:

 

 

popup page name = 1 - 50 ASCII characters. Name of the popup page.

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'PPOG-Popup1;Main'"

 

Toggles the popup page ’Popup1’ on the Main page from one state to another (On/Off).

 

Example 2:

 

SEND_COMMAND Panel,"'PPOG-Popup1'"

 

Toggles the popup page ’Popup1’ on the current page from one state to another (On/Off).

 

 

PPON

If the page name is empty, the current page is used (see example 2). If the popup page is

Activate a

already On, do not re-draw it. This command works in the same way as the ’Show Popup’

command in TPDesign4.

specific popup

 

page to launch on

Syntax:

either a specified

"'PPON-<popup page name>;<page name>'"

page or the

Variable:

current page.

 

 

popup page name = 1 - 50 ASCII characters. Name of the popup page.

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'PPON-Popup1; Main'"

 

Activates the popup page ’Popup1’ on the Main page.

 

Example 2:

 

SEND_COMMAND Panel,"'PPON-Popup1'"

 

Activates the popup page ’Popup1’ on the current page.

 

 