This section describes the solutions to possible hardware/firmware issues that could arise during the common operation of a Modero touch panel.

Troubleshooting Information

Symptom

Solution

 

 

Manifest.xma can not be found.

• Manifest.xma is the file that contains the listing for all the files. If you

An error occurs when sending a

see this error again, before attempting to send the file, uncheck the

file to a G4 panel.

Smart Transfer box. It may be necessary do a Full Clean.

 

 

When using G4 WebControl to

• During a WebControl connection to a target panel you are prompted

communicate with a target panel, a

with a G4 Authentication dialog which asks you to enter the assigned

VNC Server dialog appears on my

password for the panel (before gaining access).

screen.

• If you are ever prompted with a VNC Server dialog, you must enter

 

 

the IP Address of the target panel. This can be found within the

 

Setup > Protected Setup >System Settings page.

 

- This IP Address of the panel appears within the IP Settings

 

section of this page

 

• Enter the IP Address and click OK. You will then be prompted with

 

the G4 Authentication popup where you must enter the panel’s

 

WebControl password.

 

 

While attempting to communicate

• A Green communication icon indicates that a connection has been

directly with the Virtual Master (on

established to the target Master or target Virtual Master.

the PC) via a USB connection, I

• Launch NetLinx Studio and configure the Master Connection

can’t get my communication icon

communication settings for a Virtual Master.

to turn Green.

• Navigate to the System Settings page and toggle the Type field to

 

 

USB.

 

• Make sure the Type-A USB connector is securely connected to the

 

PC.

 

• Make sure the panel DOESN’T have the mini-USB connected and

 

TURN OFF the panel.

 

• Once the panel has turned ON THEN connect the mini-USB to the

 

Program Port. The USB icon should appear in your system tray. If it

 

doesn’t, refer to the Configuring and Using USB with a Virtual

 

Master section on page 53.

 

• The panel can take a few minutes to detect the connection to the PC.

 

 

Calibration is not working.

• After the Modero touch panel has been updated with a new firmware

 

kit (downloaded to the panel through NetLinx Studio), the calibration

 

could need to be reset.

 

• Cycling power to the panel should provide a baseline calibration for

 

the particular touch panel. Proceed to the Calibration page and reset

 

the on-screen calibration.

 

 

Panel doesn’t respond to my

• The protective cover acts to press on the entire LCD and makes

touches

calibration difficult because the user can’t calibrate on specific

 

crosshairs when the sheet is pressing on the whole LCD.

 

• Verify that the protective laminate coating on the LCD is removed

 

before beginning any calibration process.

 

 

1200V Modero Video Touch Panels

173

 

 

Page 183
Image 183
AMX NXT-1200V manual Troubleshooting Information, doesn’t, refer to the Configuring and Using USB with a Virtual