8.Navigate back to the System Settings page.

Upgrading Modero Firmware

ALL fields are then greyed-out and read-only, but still display any previous network information.

5.Press the Back button on the touch panel to return to the Protected Setup page.

6.Press the on-screen Reboot button to both save any changes and restart the panel. Remember that the panel’s connection type must be set to USB prior to rebooting the panel and prior to inserting the USB connector.

7.ONLY AFTER the unit displays the first panel page, THEN insert the mini-USB connector into the Program Port on the panel. It may take a minute for the panel to detect the new connection and send a signal to the PC (indicated by a green System Connection icon).

If a few minutes have gone by and the System Connection icon still does not turn green, complete the procedures in the following section to setup the Virtual Master and refresh the System from the Online Tree. This action sends out a request to the panel to respond and completes the communication (turning the System Connection icon green).

8.Navigate back to the System Settings page.

Step 2: Prepare NetLinx Studio for communication via the USB port

1.Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx Studio 2 > NetLinx Studio 2).

2.Select Settings > Master Communication Settings, from the Main menu to open the Master Communication Settings dialog (FIG. 72).

IP Address of computer

(not needed as this is a direct USB connection)

FIG. 72 Assigning Communication Settings for a Virtual Master

3.Click the Communications Settings button to open the Communications Settings dialog.

4.Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are working as a NetLinx Master.

5.Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate you are wanting to configure the PC to communicate directly with a panel. Everything else such as the Authentication is greyed-out because you are not going through the Master’s UI.

6.Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx Master Settings dialog (FIG. 72).