Firmware Pages and Descriptions

3.Open the Sensors Setup page (FIG. 97 on page 110) from the Protected Setup menu section.

4.Move around the panel and block the direct or indirect light from the room fixtures with your body. Take note of the drop in the lighting level being detected by the panel in response to your movements.

5.Set the Maximum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This will make sure that the panel does not react to variations in the lighting conditions of a normal working environment.

The maximum (upper level) of the dimmer should be at least 15% lower than the maximum detected level.

6.Set the minimum lighting conditions in the room (not complete darkness but the minimal lighting setup, unless complete darkness is an “operational option” for the room).

7.Set the Minimum Dimmer Brightness (Dim Mode Min Level) to a comfortable level by sitting in front of the panel. You should be able to comfortably see someone sitting behind the panel without being “blinded” by the panel.

8.Move around the panel and block the direct or indirect light from the room fixtures with your body. Take note of the drop in the lighting level being detected by the panel in response to your movements.

9.Set the Minimum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This will make sure that the panel does not react to variations in the lighting conditions of a normal working environment.

The minimum (lower level) of the dimmer should be at least 10% lower than the minimum detected level (ex: lower dimmer level at 30% if the detected lighting of the room is at 40%).

Password Setup Page

The Password Setup page (FIG. 98) centers around the properties used to assign passwords for the Modero panel pages.

FIG. 98 Password Setup page

112

1200V Modero Video Touch Panels

Page 122
Image 122
AMX NXT-1200V manual Password Setup