Dell H200 manual Installing the RPM Package With Dkms Support, Upgrading the Kernel

Page 41

Installing the RPM Package With DKMS Support

Perform the following steps to install the RPM package with DKMS support:

1Uncompress the gzipped tarball driver release package.

2Install the DKMS package using the command: rpm -ihv dkms- <version>.noarch.rpm

3Install the driver package using the command: rpm -ihv mpt2sas- <version>.noarch.rpm

NOTE: Use rpm -Uvh <package name> when updating an existing package.

4If the previous device driver is in use, you must reboot the system for the updated driver to take effect.

5Verify that the driver has been loaded with these system commands: modinfo mpt2sas and dkms status.

Upgrading the Kernel

When upgrading to a new kernel, you must reinstall the DKMS-enabled driver packages. Perform the following steps to update or install the driver for the new kernel:

1In a terminal window, type the following:

#dkms build -m <module_name> -v <module version> - k <kernel version>

#dkms install -m <module_name> -v <module version> -k <kernel version>

2To check whether the driver is successfully installed in the new kernel, type: dkms status

You see a message similar to the following one: <driver name>, <driver

version>, <new kernel version>: installed

3If the previous device driver is in use, you must reboot the system for the updated driver to take effect.

Driver Installation

41

Image 41
Contents User’s Guide July Contents Installing a Windows Server 2003, Windows Installing the Perc H200 and 6GbpsInstalling Suse Linux Enterprise Server Installing the RPM Package WithStarting the Configuration Utility Bios Fault Code Messages Booting With Multiple ControllersAssigning a Preferred Boot Device Contents Migrating and Activating a Virtual DiskAutomated Order-Status Service Firmware Package Update UtilityTechnical Support and Customer Service Corporate Contact Details Contents Safety General Page Safety Battery Disposal Page Overview OverviewGbps SAS HBA Hardware Architecture Operating System SupportRAID Levels About RAIDRAID Terminology Example of RAID Stripe element Stripe element 1 duplicated Overview Perc H200 and 6Gbps SAS HBA Features Perc H200 and 6Gbps SAS HBA FeaturesSpecifications of Perc H200 RAID 0, RAID Specifications of 6Gbps SAS HBA Lists the specifications of the 6Gbps SAS HBALater 64-bit only LED Port Activity Feature for 6Gbps SAS HBA Only Unsupported Drives Physical Disk Cache PolicyHardware Installation Hardware InstallationInstalling the Perc H200 and 6Gbps SAS HBA Cards SAS HBA Connecting the Cable for Perc H200 Connecting the Cable for 6Gbps SAS HBA Installing the Perc H200 Modular Card To install your new storage controller card Driver Installation Driver InstallationCreating the Driver Media Installing the Windows DriverPre-Installation Requirements Boot the system using the Windows Server 2003 media Driver Installation Locate Driver Files screen Follow the step below according to your operating system Updating the Windows DriverCreating a DUD Installing Linux DriverUnzip the package using gunzip Untar the file using tar -xvf Creating a DUD Using Dkms Installing Suse Linux Enterprise Server Using the DUD Upgrading the Kernel Installing the RPM Package With Dkms SupportDriver Installation Bios Fault Code Messages Perc H200 and 6Gbps SAS HBA BiosPerc H200 and 6Gbps SAS HBA Bios Post MessagesBooting With Multiple Controllers Configuration UtilityStarting the Configuration Utility Functions PerformedFunctions of the Configuration Utility Description RAID Configuration and Management Screens Volume Field Descriptions Select New Volume TypeCreate New Volume RAID Volume Field Descriptions Manage Volume View VolumeManage Volume Field Descriptions Assign a hot spare, RAID 1 and RAID 10 configurations onlyExit Screen Performing Configuration TasksCreating a RAID 0 Virtual Disk Creating a RAID 1 Virtual Disk Creating a RAID 10 Virtual Disk Perc H200 and 6Gbps SAS HBA Bios Activating a Virtual Disk Viewing Virtual Disk PropertiesDeleting a Virtual Disk Migrating and Activating a Virtual DiskReplacing and Rebuilding a Degraded Virtual Disk Hot Spare FailoverAssigning a Preferred Boot Device Current Boot Device set to volume at handle Bios Boot Order TroubleshootingTroubleshooting Background ActivitiesGeneral Issues Physical Disk Related Issues For Configuration Utility Configuration Utility Error MessagesConfiguration Utility Bios Error Messages Meaning Bios Error MessagesBios Error Messages MessageMeaning Bios Fault 01 No I/O port assigned to the adapter Message indicates that the preferred boot Troubleshooting Appendix a Updating the Firmware Firmware Package Update UtilityUpdating the Firmware Appendix a Updating the Firmware Appendix B Getting Help Technical Support and Customer ServiceGetting Help Online Services Product Information Dell Enterprise Training Problems With Your OrderAutomated Order-Status Service Before You Call Returning Items for Warranty Repair or CreditAppendix C Regulatory Notices Regulatory NoticesAppendix C Regulatory Notices Appendix D Corporate Contact Details Taiwan Only Corporate Contact Details Taiwan OnlyAppendix D Corporate Contact Details Taiwan Only Glossary GlossaryDkms Glossary Operating System PHY RAID Sata Smart Page Glossary Index IndexIndex