HP J3175A, J3177A manual LED Behavior, When the self test completes successfully

Page 15

Installing the Switch 208/224

Installation Steps

When the switch is powered on, it performs its diagnostic self test. With the Switch Management Module installed, the self test takes approxi- mately 15 seconds to complete. Without the Switch Management Module, the test completes in approximately 4 seconds.

LED Behavior:

During the self test:

Initially, all LEDs are on.

With a Management Module installed, the switch port LEDs all go off after approximately 10 seconds, and the Management Module Self Test and Fault LEDs stay on for an additional 5 to 7 seconds.

When the self test completes successfully:

The Power LED and, if an RPS is connected, the RPS LED remain on. The “100” LED for port A also stays on.

The Fault LED on the switch, and the Self Test and Fault LEDs on the Management Module go off.

The port LEDs go into their normal operational mode, if they are connected to active network devices.

If the LED display is different than what is described above, especially if any Fault LEDs stay on for more than 30 seconds or flash, the self test has not completed correctly. Refer to chapter 3, “Troubleshooting” for diag- nostic help.

Installing the Switch 208/224

1-7

Image 15
Contents HP AdvanceStack Switch 208/224 Page World Wide Web HP Customer Support ServicesHow to get the latest software/agent firmware HP FTP Library ServiceHP First Fax Retrieval Service Additional HP Support ServicesLocation Phone Number Installation and Reference Guide HP AdvanceStack Switch 208/224Publication Number Contents Index Installing the Switch 208/224 Installing the Switch 208/224Installation Steps Installing the Switch 208/224Included Parts Installation Precautions Prepare the Installation Site Installing Modules Install Any Optional ModulesInstalling Transceivers 100Base-T transceiver modules into the Switch 208/224Do not install any 100VG transceiver modules in this slot Verify the Switch’s Operation LED Behavior When the self test completes successfullyMounting the Switch in a Rack or Cabinet Mount the SwitchInsert a screw into the top hole of a close 0.5-inch Install additional screw Mounting the Switch on a Horizontal Surface Mounting the Switch on a WallConnect the Switch to a Power Source To connect Using RJ-45 Connectors 10 Mbit/s and 100 Mbit/s portsConnect the Network Cables 100Base-T Xcvr SlotCondition Diagnostic Tip Installing Switch 208/224As a Segment Switch Switch 208TSample Network Topologies As a Desktop Switch Switch 224T PCs and peripheralsServer Switch 224T Switch 208T Connecting to a Backbone SwitchFddi Campus Backbone Installing the Switch 208/224 SwitchCable Management Where to Go From HereFeatures Switch 208/224 DescriptionFront of the Switches Switch 208/224 DescriptionNetwork Ports State Meaning LEDsManagement Slot Management Module FeaturesExpansion Slot Back of the SwitchesPower Connectors Redundant Power Supply RPS ConnectorAddress Table Operation Switch OperationSimultaneous Network Communications Page Solutions to Common Problems TroubleshootingWrong network speed connected -- You have connected a TroubleshootingDiagnostic Tips LED Error IndicationsDiagnostic Tests Testing the SwitchTesting Twisted-Pair Cabling Testing Switch-to-Device Network Communications Testing End-to-End Network CommunicationsHP BBS Resetting the SwitchTwisted-Pair Cable/Connector Pin-Outs Cables and ConnectorsCables and Connectors White/orange Twisted-Pair Cross-Over Cable Fiber-Optic CablesTwisted-Pair Cable Pin Assignments Twisted-Pair Straight-Through CableEnvironmental SpecificationsPhysical ElectricalElectromagnetic ConnectorsSafety SpecificationsMounting Precautions Safety and Regulatory StatementsSafety and Regulatory Statements Power PrecautionsSafety Information GroundingServicing Tible de causer des dommages à léquipement Informations concernant la sécuritéHinweise zur Sicherheit Attrezzature Considerazioni sulla sicurezzaResultar en averías al equipo Consideraciones sobre seguridadSafety Information Japanese Canada Regulatory StatementsFCC Class a Statement for U.S.A. Only European CommunityDeclaration of Conformity Numerics IndexMounting switch on … 1-11 HP Redundant Power Supply RPS Rack Page Page 5966-5225