HP J3177A, J3175A manual Front of the Switches, Network Ports, Switch 208/224 Description

Page 28

Switch 208/224 Description

Switch 208/224 Description

Front of the Switches

Front of the Switches

 

 

 

4 LEDs for

LED indicating

 

 

 

 

expansion module

Port 1 is disabled

 

Power

Fault

RPS

LEDs for

 

LEDs for

LED

LED

LED

100 Mbit/s ports

10 Mbit/s ports

HP J3175A

Switch 208T

HP J3177A

Switch 224T

slot for

100 Mbit/s ports:

 

 

10 Mbit/s RJ-45ports

Switch Management Module

- one fixed RJ-45

 

- one

 

 

Network Ports

8 or 24 10 Mbit/s RJ-45 Ethernet/IEEE 802.3 ports

one fixed 100 Mbit/s RJ-45 100Base-TX port

one 100 Mbit/s transceiver slot for installing HP 100Base-TX or 100Base- FX transceivers

All the twisted-pair ports are wired as MDI-X. Therefore, to connect end nodes or other MDI-type devices to these ports, use “straight-through” twisted-pair cable; to connect hubs, switches, or other MDI-X-type devices to these ports, use “crossover” twisted-pair cable. See appendix A, “Cables and Connectors” for descriptions of these cables.

The cabling to the transceiver port depends on the type of transceiver installed. For more information, refer to the manual that came with the transceiver.

2-2

Image 28
Contents HP AdvanceStack Switch 208/224 Page HP Customer Support Services How to get the latest software/agent firmwareHP FTP Library Service World Wide WebAdditional HP Support Services HP First Fax Retrieval ServiceLocation Phone Number HP AdvanceStack Switch 208/224 Installation and Reference GuidePublication Number Contents Index Installing the Switch 208/224 Installing the Switch 208/224Installing the Switch 208/224 Installation StepsIncluded Parts Prepare the Installation Site Installation PrecautionsInstall Any Optional Modules Installing Modules100Base-T transceiver modules into the Switch 208/224 Installing TransceiversDo not install any 100VG transceiver modules in this slot Verify the Switch’s Operation When the self test completes successfully LED BehaviorMount the Switch Mounting the Switch in a Rack or CabinetInsert a screw into the top hole of a close 0.5-inch Install additional screw Mounting the Switch on a Wall Mounting the Switch on a Horizontal SurfaceConnect the Switch to a Power Source Using RJ-45 Connectors 10 Mbit/s and 100 Mbit/s ports Connect the Network Cables100Base-T Xcvr Slot To connectSwitch 208/224 Condition Diagnostic Tip InstallingSwitch 208T As a Segment SwitchSample Network Topologies Switch 224T PCs and peripherals As a Desktop SwitchServer Connecting to a Backbone Switch Fddi Campus Backbone Installing the Switch 208/224Switch Switch 224T Switch 208TWhere to Go From Here Cable ManagementSwitch 208/224 Description FeaturesSwitch 208/224 Description Front of the SwitchesNetwork Ports LEDs State MeaningManagement Module Features Management SlotBack of the Switches Power ConnectorsRedundant Power Supply RPS Connector Expansion SlotSwitch Operation Address Table OperationSimultaneous Network Communications Page Troubleshooting Solutions to Common ProblemsTroubleshooting Wrong network speed connected -- You have connected aLED Error Indications Diagnostic TipsTesting the Switch Diagnostic TestsTesting Twisted-Pair Cabling Testing End-to-End Network Communications Testing Switch-to-Device Network CommunicationsResetting the Switch HP BBSCables and Connectors Twisted-Pair Cable/Connector Pin-OutsCables and Connectors White/orange Fiber-Optic Cables Twisted-Pair Cable Pin AssignmentsTwisted-Pair Straight-Through Cable Twisted-Pair Cross-Over CableSpecifications PhysicalElectrical EnvironmentalConnectors SafetySpecifications ElectromagneticSafety and Regulatory Statements Mounting PrecautionsPower Precautions Safety and Regulatory StatementsGrounding Safety InformationServicing Informations concernant la sécurité Tible de causer des dommages à léquipementHinweise zur Sicherheit Considerazioni sulla sicurezza AttrezzatureConsideraciones sobre seguridad Resultar en averías al equipoSafety Information Japanese Regulatory Statements FCC Class a Statement for U.S.A. OnlyEuropean Community CanadaDeclaration of Conformity Index NumericsMounting switch on … 1-11 HP Redundant Power Supply RPS Rack Page Page 5966-5225