The
Table 23 Seven-segment LED description (I)
System status LED | Description | ||
(PWR) status | |||
|
|
The LED displays numbers one by one.
Flashing green
POST is running, and the LED displays the ongoing test item ID.
The LED displays flashing numbers.
Flashing red
POST has failed, and the LED flashes the ID of the failed test item.
A bar rotates clockwise around the LED.
Flashing green | Software is loading. |
The LED displays a flashing F character.
Steady red | The switch is experiencing a fan | |
failure. | ||
|
The LED displays a flashing t character.
Steady red
The switch is in an
| The LED displays a capital C character. | The switch is the command switch in a |
|
| |
|
| cluster. |
| The LED displays an S character. | The switch is a member switch in a |
|
| |
|
| cluster. |
Steady green | The LED displays a lowercase c character. | The switch is a candidate switch for a |
| ||
|
| |
|
| cluster. |
The LED displays a number.
The member ID of the switch in an IRF fabric.
The
Table 24 Seven-segment LED description (II)
Port mode LED | System status LED | Description | ||
(Mode) status | (PWR) status | LED (Unit) status | ||
|
|
| The LED displays |
Flashing green (1 | Steady green | different signs. |
Hz) (PoE mode) |
| |
|
|
81 - 100
61 - 80%
41 - 60%
21 - 40%
0 - 20%
For example, the sign indicates that the switch is outputting 0 to 20% of the maximum PoE output power.
78