HP 5120 SI, 5120 48G, 5120 EI, E5500-48-POE manual 10/100/1000Base-T Ethernet port LED, SFP port LED

Page 84

10/100/1000Base-T Ethernet port LED

Each 10/100/1000Base-T auto-sensing Ethernet port has a status LED to show port operating status and activities. The port mode LED indicates the type of information (for example, port rate or duplex mode) that the port LEDs are showing. You can use the port LED mode switching button to change the type of displayed port information.

Table 25 10/100/1000Base-T auto-sensing Ethernet port LEDs description

Port mode LED (Mode)

Port LED status

Description

status

 

 

 

 

The port is operating at 1000 Mbps. The port LED

 

Steady green

fast flashes when the port is sending or receiving

 

 

data.

 

 

 

Steady green (rate mode)

 

The port is operating at 10/100 Mbps. The port LED

Steady yellow

fast flashes when the port is sending or receiving

 

 

 

data.

 

 

 

 

Flashing yellow (3 Hz)

POST has failed on the port.

 

 

 

 

Off

No link is present on the port.

Flashing green (1 Hz) (PoE mode, available only for PoE switches)

Steady green

PoE power supply is normal.

 

 

 

The device attached to the port requires power

Flashing green (1 Hz)

higher than the maximum or currently available PoE

 

output power on the port.

 

 

 

The port is experiencing a PoE failure.

Steady yellow

The port is not supplying power, because the device

 

attached to the port is not a powered device.

 

Flashing yellow (3 Hz)

POST has failed on the port.

 

 

 

 

Off

The port is not supplying PoE power.

 

 

 

 

 

The port is operating in full duplex mode. The port

 

Steady green

LED fast flashes when the port is sending or

 

 

receiving data.

 

 

 

Steady yellow (duplex

 

The port is operating in half duplex mode. The port

Steady yellow

LED fast flashes when the port is sending or

mode)

 

receiving data.

 

 

 

 

 

 

Flashing yellow (3 Hz)

POST has failed on the port.

 

 

 

 

Off

No link is present on the port.

 

 

 

SFP port LED

Each 1000Base-X SFP port has a status LED to show port operating status and activities. The port mode LED indicates the type of information (for example, port rate or duplex mode) that the port LEDs are showing. You can use the port LED mode switching button to change the type of displayed port information.

79

Image 84
Contents HP 5120 EI & 5120 SI Switch Series Page Contents Page Iii Models in the HP 5120 EI Switch Series Models in the HP 5120 SI Switch SeriesProduct overview Type Product code HP description AliasRegulatory Model Numbers in the HP 5120 8G SI Switch Series 5120-24G EI 2 slots/5120-24G EI TAA 2 slots panel views5120-48G EI 2 slots/5120-48G EI TAA 2 slots panel views 5120-24G EI panel views 5120-48G EI switch does not support interface cards 5120-48G EI panel viewsFront panel Front panel 5120-8G SI panel views 5120-16G SI panel views5120-24G SI panel views 5120-48G SI panel views5120-8G-PPoE+ SI panel views 5120-8G-PoE+ SI panel views5120-24G-PPoE+ SI panel views 5120-24G-PoE+ SI panel views Preparing for installation Safety recommendationsExamining the installation site Temperature/humidityCleanness Laser safetyDust concentration limit in the equipment room Harmful gas limits in the equipment roomInstallation tools Installing the switch Hardware installation flowInstalling a 5120 EI switch in a 19-inch rack Installation methodsMounting brackets Rack-mounting by using only front mounting brackets Mounting bracket kit shipped with the 5120 EI switchesChassis Front mounting brackets Rear mounting brackets Attach the front mounting brackets to the chassis Attach the front mounting brackets to the rack Rack-mounting by using front and rear mounting brackets Attach the rear mounting brackets to a rack Mount the switch in the rack Installing a 5120 SI switch in a 19-inch rack Attach the front brackets to the rackAttaching the mounting brackets to the switch chassis To attach the mounting brackets to the switch chassisChassis Bracket view Mounting position Front mounting position 5120-16G SI/5120-24G SI Front mounting position 5120-8G-PoE+ SI/5120-8G-PPoE+ SI Rack-mounting the switch Mount the switch in a rack 5120-16G SI Mounting the switch on a workbench Mounting the switch to a wallInstallation procedure Introduction to wall anchor kitModels supporting wall mounting Model Hole distanceMounting the switch through magnet mounting Introduction to magnetic mounting kitMagnet mounting kit Grounding the switch Grounding the switch with a grounding stripPage Make a grounding cable connector Grounding the switch by using the AC power cord Ground through the PE wire of the AC power cordConnecting the power cord Connecting the AC power cordConnecting the switch to a +12 VDC output RPS Connect the AC power cord to the 5120-48G EI switchConnecting the switch to a -52 to -55 VDC output RPS Connect the RPS cable to the -52 to -55 RPS receptacleInstalling an interface card Remove the filler panel over an interface card slotInstalling/removing a dedicated CX4/SFP+ cable Removing an interface cardVerifying the installation Removing a dedicated CX4/SFP+ cableAccessing the switch for the first time Setting up the configuration environmentConnecting the console cable Connection procedureSetting terminal parameters Connection descriptionSet the serial port used by the HyperTerminal connection Set the serial port parametersHyperTerminal window Powering on the switch Verification before power-onPowering on the switch Boot menu options DescriptionChanging the startup mode Enter 9 to change the startup modeEnter Y at the prompt Finished User interface aux0 is available Press Enter to get started Setting up an IRF fabric IRF fabric setup flowchartTo set up an IRF fabric Planning IRF fabric setup Planning IRF fabric size and the installation siteIdentifying the master switch and planning IRF member IDs Step DescriptionPlanning IRF topology and connections 5120 EI IRF fabric in daisy chain topologyIdentifying physical IRF ports on the member switches 5120 SI IRF fabric in daisy chain topologySwitch chassis Candidate physical Requirements IRF ports Planning the cabling schemePhysical IRF port requirements Page Configuring basic IRF settings Shows the IRF fabric topologyConnecting the physical IRF ports Accessing the IRF fabric to verify the configurationDisplay and maintain IRF configuration and running status To do … Use the command…Maintenance and troubleshooting Password lossPower supply failure Console login password lossAC input Fan failure only for the 5120 EI switches Configuration terminal problemsLED behaviors that identify a fan failure Mark StateAppendix a Technical specifications Physical specificationsChassis dimensions and weights Chassis Dimensions H × W × D WeightEnvironmental specifications Power specificationsPower input types Chassis Operating temperature Relative humidityAC input voltage specifications RPS DC input voltage specifications and RPS compatibilityPower consumption specifications for non-PoE switches Power consumption specifications for PoE switches Cooling systemChassis Fixed fans Interface cards only for the 5120 EI switches Appendix B FRUs and compatibility matrixesGE SFP transceiver modules GE SFP+ transceiver modulesSFP+ cables Product code Cable description Cable lengthProduct code Cable description Connector type Cable length GE XFP transceiver modulesCX4 cables UTP/STP Page Appendix C Ports and LEDs PortsConsole port 10/100/1000Base-T Ethernet portLEDs for the 5120 EI switches Combo interface only available on the 5120 EI switchesSystem status LED Port mode LED RPS status LEDSeven-segment LED Seven-segment LED description Port mode LED Mode Port LED status Description Status 10/100/1000Base-T Ethernet port LEDSFP port LED LEDs for the 5120 SI switches Power LEDInterface card status LED RPS status LED description Ethernet port LED description 5120-48G SIStatus Description Port mode LED Mode Port LED Ethernet port LEDs description 5120-16G SI/5120-24G SI1000Base-X SFP port LED 1000Base-X SFP port LEDs descriptionSupport and other resources Contacting HPRelated information Conventions Convention DescriptionConvention Description Network topology icons Verifying the installation,43 Index