HP 5120 EI, 5120 SI, 5120 48G, E5500-48-POE manual Boot menu options, Description

Page 54

3.Display all files in flash

4.Delete file from flash

5.Modify bootrom password

6.Enter bootrom upgrade menu

7.Skip current configuration file

8.Set bootrom password recovery

9.Set switch startup mode

0. Reboot

Enter your choice(0-9):

Table 11 Boot menu options

Item

Description

1.

Download application file to flash

Download a system software image file to the Flash memory.

 

 

 

2.

Select application file to boot

Select the system software image file to boot.

 

 

 

3.

Display all files in flash

Display all files in the Flash memory.

 

 

 

4.

Delete file from flash

Delete files from the Flash memory.

 

 

 

5.

Modify bootrom password

Modify the Boot ROM password.

 

 

 

6.

Enter bootrom upgrade menu

Access the Boot ROM update menu.

 

 

 

 

 

Start the switch with the factory default configuration. This is a

7.

Skip current configuration file

one-time operation and does not take effect at the next reboot. You

 

 

use this option when you forget the console login password.

 

 

 

 

 

Disable or enable the Boot ROM password recovery function. By

8.

Set bootrom password recovery

default, Boot ROM recovery is enabled. You can disable this function

 

 

to protect system security.

 

 

 

9.

Set switch startup mode

Set the startup mode to full mode or fast mode, as described in

Changing the startup mode.”

 

 

 

 

 

0.

Reboot

Restart the switch.

 

 

 

 

 

 

NOTE:

The system by default has no Boot ROM password. HP recommends that you set a Boot ROM password immediately after you access the Boot menu.

If you perform no operation or press any key other than Ctrl + B within one second, the system automatically starts up when the remaining time becomes zero, and displays the following information:

Auto-booting...

Decompress Image................................................................

................................................................................

................................................................................

................................................................................

................................................................................

................................................................................

................................................................................

................................................................................

................................................................................

49

Image 54
Contents HP 5120 EI & 5120 SI Switch Series Page Contents Page Iii Product overview Models in the HP 5120 EI Switch SeriesModels in the HP 5120 SI Switch Series Type Product code HP description AliasRegulatory Model Numbers in the HP 5120 8G SI Switch Series 5120-24G EI 2 slots/5120-24G EI TAA 2 slots panel views5120-48G EI 2 slots/5120-48G EI TAA 2 slots panel views 5120-24G EI panel views 5120-48G EI switch does not support interface cards 5120-48G EI panel viewsFront panel Front panel 5120-8G SI panel views 5120-16G SI panel views5120-24G SI panel views 5120-48G SI panel views5120-8G-PPoE+ SI panel views 5120-8G-PoE+ SI panel views5120-24G-PPoE+ SI panel views 5120-24G-PoE+ SI panel views Examining the installation site Preparing for installationSafety recommendations Temperature/humidityDust concentration limit in the equipment room CleannessLaser safety Harmful gas limits in the equipment roomInstallation tools Installing the switch Hardware installation flowInstalling a 5120 EI switch in a 19-inch rack Installation methodsMounting brackets Rack-mounting by using only front mounting brackets Mounting bracket kit shipped with the 5120 EI switchesChassis Front mounting brackets Rear mounting brackets Attach the front mounting brackets to the chassis Attach the front mounting brackets to the rack Rack-mounting by using front and rear mounting brackets Attach the rear mounting brackets to a rack Mount the switch in the rack Installing a 5120 SI switch in a 19-inch rack Attach the front brackets to the rackAttaching the mounting brackets to the switch chassis To attach the mounting brackets to the switch chassisChassis Bracket view Mounting position Front mounting position 5120-16G SI/5120-24G SI Front mounting position 5120-8G-PoE+ SI/5120-8G-PPoE+ SI Rack-mounting the switch Mount the switch in a rack 5120-16G SI Mounting the switch on a workbench Mounting the switch to a wallModels supporting wall mounting Installation procedureIntroduction to wall anchor kit Model Hole distanceMounting the switch through magnet mounting Introduction to magnetic mounting kitMagnet mounting kit Grounding the switch Grounding the switch with a grounding stripPage Make a grounding cable connector Grounding the switch by using the AC power cord Ground through the PE wire of the AC power cordConnecting the power cord Connecting the AC power cordConnecting the switch to a +12 VDC output RPS Connect the AC power cord to the 5120-48G EI switchConnecting the switch to a -52 to -55 VDC output RPS Connect the RPS cable to the -52 to -55 RPS receptacleInstalling an interface card Remove the filler panel over an interface card slotInstalling/removing a dedicated CX4/SFP+ cable Removing an interface cardVerifying the installation Removing a dedicated CX4/SFP+ cableConnecting the console cable Accessing the switch for the first timeSetting up the configuration environment Connection procedureSetting terminal parameters Connection descriptionSet the serial port used by the HyperTerminal connection Set the serial port parametersHyperTerminal window Powering on the switch Verification before power-onPowering on the switch Boot menu options DescriptionChanging the startup mode Enter 9 to change the startup modeEnter Y at the prompt Finished User interface aux0 is available Press Enter to get started Setting up an IRF fabric IRF fabric setup flowchartTo set up an IRF fabric Identifying the master switch and planning IRF member IDs Planning IRF fabric setupPlanning IRF fabric size and the installation site Step DescriptionPlanning IRF topology and connections 5120 EI IRF fabric in daisy chain topologyIdentifying physical IRF ports on the member switches 5120 SI IRF fabric in daisy chain topologySwitch chassis Candidate physical Requirements IRF ports Planning the cabling schemePhysical IRF port requirements Page Configuring basic IRF settings Shows the IRF fabric topologyDisplay and maintain IRF configuration and running status Connecting the physical IRF portsAccessing the IRF fabric to verify the configuration To do … Use the command…Power supply failure Maintenance and troubleshootingPassword loss Console login password lossAC input LED behaviors that identify a fan failure Fan failure only for the 5120 EI switchesConfiguration terminal problems Mark StateChassis dimensions and weights Appendix a Technical specificationsPhysical specifications Chassis Dimensions H × W × D WeightPower input types Environmental specificationsPower specifications Chassis Operating temperature Relative humidityAC input voltage specifications RPS DC input voltage specifications and RPS compatibilityPower consumption specifications for non-PoE switches Power consumption specifications for PoE switches Cooling systemChassis Fixed fans Interface cards only for the 5120 EI switches Appendix B FRUs and compatibility matrixesGE SFP transceiver modules GE SFP+ transceiver modulesSFP+ cables Product code Cable description Cable lengthProduct code Cable description Connector type Cable length GE XFP transceiver modulesCX4 cables UTP/STP Page Console port Appendix C Ports and LEDsPorts 10/100/1000Base-T Ethernet portLEDs for the 5120 EI switches Combo interface only available on the 5120 EI switchesSystem status LED Port mode LED RPS status LEDSeven-segment LED Seven-segment LED description Port mode LED Mode Port LED status Description Status 10/100/1000Base-T Ethernet port LEDSFP port LED LEDs for the 5120 SI switches Power LEDInterface card status LED RPS status LED description Ethernet port LED description 5120-48G SIStatus Description Port mode LED Mode Port LED Ethernet port LEDs description 5120-16G SI/5120-24G SI1000Base-X SFP port LED 1000Base-X SFP port LEDs descriptionSupport and other resources Contacting HPRelated information Conventions Convention DescriptionConvention Description Network topology icons Verifying the installation,43 Index