Table 7 Recovery Manager for Microsoft Exchange Event Messages (continued)
Event ID | Error Message | Description/Action |
5054 | 3PARVSS5054: ERROR: CLI: <command>. | The command submitted to the CLI has generated |
|
| an error. |
|
| • Check the Application Log of the Event Viewer |
|
| for more information. |
5055 | 3PARVSS5055: ERROR: <Token>: Invalid | Unable to identify requested information received |
| token. | from the HP 3PAR Storage System. |
|
| • Check that your HP 3PAR Storage System version |
|
| is supported by VSS Provider and that there are |
|
| no network problems that could result in a partial |
|
| data transmission. |
|
| • To determine the version for a particular HP |
|
| 3PAR Storage System, run the showversion |
|
| command. |
|
| • For the VSS Provider version, run vssadmin |
|
| list providers and check the VSS Provider |
|
| entry that specifies the version and other details. |
5056 | 3PARVSS5056: ERROR: Could not open | Unable to build the internal virtual volume database. |
| volume mapping file: <Volume Map File>. | • Check that your HP 3PAR Storage System version |
|
| |
|
| is supported by VSS Provider and that there are |
|
| no network problems that could result in a partial |
|
| data. transmission. |
|
| • To get the version for a particular HP 3PAR |
|
| Storage System, run showversion. |
|
| • For the VSS Provider version, run vssadmin |
|
| list providers and check the VSS Provider |
|
| entry that specifies the version and other details. |
5057 | 3PARVSS5057: ERROR: Could not open file: | Unable to open the designated file for internal |
| <File Name>. | processing. |
|
| • Check that you have the correct privileges to |
|
| access the Windows temporary folder. |
5058 | 3PARVSS5058: ERROR: Could not create | Unable to create the designated output file for |
| file: <File Name>. | internal processing. |
|
| • Check that you have the correct privileges to |
|
| access the Windows temporary folder. |
5059 | 3PARVSS5059: ERROR: SYSTEM: <Error | A Windows system decode error code has been |
| Code &/or Description>. | generated. |
|
| • To get a more detailed description, consult |
|
| msdn.microsoft.com or Windows Help. |
5061 | 3PARVSS5061: ERROR: IOCTL inquiry call | Unable to perform an inquiry on the targeted |
| failed. | volume. This might be caused by specifying an |
|
| invalid volume during snapshot creation. |
• Make sure all volumes that participate in the snapshot process are valid and HP 3PAR storage volumes.
• Check to see that the volumes are accessible and are not in a bad or offline state.