Physical Specifications

Table C-1: Physical Specifications

Feature

 

Metric

U.S.

Dimensions

Width

431.8 mm

17.0 in

 

 

 

 

 

 

 

Height

88.9 mm

3.5 in

 

 

 

 

 

 

 

Depth*

464.8 mm

18.3 in

 

 

 

 

Weight

 

23 kg

50 lb

 

 

 

 

*With front bezel installed

 

 

 

 

 

 

 

 

HP Uninterruptible Power System R1500 XR Models User Guide

C-1

Image 46
Contents HP Uninterruptible Power System R1500 XR Models User Guide Page Contents Chapter Troubleshooting Appendix B Electrostatic Discharge Page About This Guide Important Safety InformationSymbols on Equipment Audience AssumptionsRack Stability Symbols in TextRelated Documents Technical Support Getting HelpReader’s Comments HP Website Authorized ResellerOverview Standard UPS FeaturesCommunications Port Overcurrent Protection UPS R1500 XR ModelsNetwork Transient Protector UPS R1500 XR ModelsFront panel configuration Front PanelRear Panels Rear panel of R1500 XR NARear panel of R1500 XR JPN Rear panel of R1500 XR H INT’L Hardware Options Power Management SoftwareUPS Hardware Options Option Part Number$25,000 Computer Load Protection Guarantee Remote Emergency Power Off PortWarranties Pre-Failure Battery Warranty Operation Front Panel Controls and LED IndicatorsDescription Meaning/Function Modes of Operation LEDPlacing the UPS in Operate Mode Charging the BatteriesReturning to Standby Mode Placing the UPS in Standby modeTest/Alarm Reset button Initiating a Self-TestSilencing an Audible Alarm Audible AlarmsShutting Down the System Configuration Placing the UPS in Configure ModeConfiguration Parameters Configuration ParametersParameter LED Parameter Name Explanation when illuminated Changing Configuration Parameters Available Voltage SettingsConfiguration Precautions Battery MaintenanceCharging Batteries Determining When to Replace Batteries Obtaining New BatteriesReplacing Batteries Removing the Battery PackPreparing the UPS Remove the two screws to obtain access to the battery pack Disconnecting the battery cable from the circuit board Testing the New Battery Pack Installing a New Battery PackDisposing of Used Batteries Care and Storage of Batteries Troubleshooting TroubleshootingTroubleshooting Symptom Possible Cause Suggested ActionTroubleshooting Troubleshooting Repairing the UPS Federal Communications Commission Notice Regulatory Compliance NoticesRegulatory Compliance Identification Numbers Class a EquipmentClass B Equipment ModificationsEuropean Union Notice Canadian Notice Avis CanadienCables Japanese Notice China Taiwan Notice Battery Replacement Notice Electrostatic Discharge Grounding MethodsTable C-1 Physical Specifications SpecificationsPhysical Specifications Feature MetricInput Specifications Table C-2 Input SpecificationsTable C-3 Output Specifications Output SpecificationsTable C-4 Output Specifications Table C-5 Battery Specifications Battery SpecificationsEnvironmental Specifications Table C-6 Environmental SpecificationsIndex Index-2 Index-3