Table 13 HP array event information packet (EIP) types (continued)

Code

Title

Description

0D

Executive Services System Time Change

A change in system time occurred.

0E

Storage System Management Interface Entity

A Storage System Management Interface entity was

 

Creation or Deletion

created or deleted.

0F

Storage System Management Interface Entity Attribute

An attribute of a Storage System Management

 

Change

Interface entity has changed.

10

System Services HSV210 Controller State Change

A controller state change occurred.

11

Disk Enclosure Environmental Monitoring Unit

Status of a disk enclosure element has changed.

 

Services Status Change

 

12

Fibre Channel Services Physical Disk Drive/Mirror

Unexpected work was received from a physical disk

 

Port Unexpected Work Encountered

drive or the mirror port.

13

Fibre Channel Services Physical Disk Drive/Mirror

Summary of errors encountered while attempting to

 

Port/Drive Enclosure Environmental Monitoring Unit

access a physical disk drive, the mirror port, or a

 

Error Summary

Drive Enclosure Environmental Monitoring Unit.

14

Diagnostic Operations Generator Detected Failure

A failure was detected during the execution of a

 

 

diagnostic.

15

Container Services Management Operation has

An operation on a Disk Group has started or

 

started or completed

completed.

16

Data Replication Manager Time Report

An HSV210 controller has received a time report

 

 

message.

17

Fibre Channel Services Fibre Channel Port Loop

A new device map has been generated on a Fibre

 

Config

Channel port.

18

Storage System State Services Redundant Storage

A Redundant Storage Set state change occurred.

 

Set State Change

 

19

System Data Center Services Status Change

Status of a System Data Center element has changed.

1A

System Services Code Load Operation Update

A code load operation has occurred.

1C

Fault Manager Termination Event

An HSV210 controller operation was terminated due

 

 

to an unrecoverable event detected by either software

 

 

or hardware or due to an action initiated via the

 

 

Storage System Management Interface.

1D

Fault Manager Termination Event (old Termination

An HSV210 controller operation was terminated due

 

Event Information Header)

to an unrecoverable event detected by either software

 

 

or hardware or due to an action initiated via the

 

 

Storage System Management Interface.

1E

General Storage System State Services State

General Storage System state information to be

 

Information Event

reported.

Coupled crash control codes

Table 14 HP array coupled crash control codes

Code

Description

0

Other controller should not perform a coupled crash.

1

Other controller should perform a coupled crash.

98 HP array event code formats and descriptions

Image 98
Contents HP P6000 Command View User Guide AbstractSee Internet Protocol support Contents Maintaining and managing HP P6000/EVA storage systems Configuring HP P6000 Command View advanced tasksTroubleshooting HP P6000 Command View Monitoring storage system eventsComponents Glossary 100 Index 103 Support and other resourcesHP array event code formats and descriptions Prerequisites HP P6000 Command View software suiteOverview HP P6000 Command View features Server-based and array-based managementServer-based configuration Array-based configuration HP Management Integration FrameworkUser interface Storage systems point of view Hardware-SeeHardwareSettings point of view Settings point of viewRunning server-based HP P6000 Command View from the desktop Accessing HP P6000 Command ViewBrowsing to server-based HP P6000 Command View Browsing to array-based HP P6000 Command ViewInternet Protocol support IP address formatsArray-based HP P6000 Command View security groups Managing security and passwordsServer-based HP P6000 Command View security groups Password protection for storage systemsConsiderations Enabling management of a password-protected storage systemPassword formats Disabling management of a password-protected storage system Setting a password for HP EVA storage systemsDisabling management of a password-protected storage system Single sign-on from HP Systems Insight ManagerManaging security and passwords License types Licensing HP P6000/EVA storage systemsLicenses to use and license keys Instant-on licensesData migration licenses Model upgrade licensingModel upgrade support Fcip licensesRetrieving licenses Configuring email to receive LTUsActivating an instant-on license Entering license keysAdding an LTU Importing licensesValidating the license Deleting incorrectly entered license keys Displaying temporary license expiration dateWorking with disk groups Provisioning storageDisk groups General guidelines Disk typesDisk group types Number of physical disks in a group Disk group occupancy and occupancy alarm levelDisk group capacity Redundancy Vraid levels Working with virtual disks in HP P6000 Command View Virtual disksVirtual disks Working with hosts in HP P6000 Command View HostsMirrorclone migration PresentationOnline virtual disk migration Thin provisioningThin provisioned disk Snapclones Replicating storageHP P6000 Business Copy software Snapshot guidelines SnapshotsSnapshot types Monitoring snapshot spaceMirrorclones Mirrorclone guidelinesSynchronized mirrorclone guidelines Fractured mirrorclone guidelinesContainers Mirrorclone statesPlanning for host I/O workloads Using containers preallocationOptimizing replication performance Optimizing snap creationMinimizing simultaneous replication operations Minimizing snapclone workloadsMinimizing the number of snapshots DR groups HP P6000 Continuous Access softwareWorking with DR groups in HP P6000 Command View Creating DR groups Data replication protocol optionsReplicating storage Maintaining and managing HP P6000/EVA storage systems Initializing storage systemsUser-initiated service mode USER-INITIATED Service Mode Active on this Storage SystemShutting down the storage system Uninitializing storage systemsStarting the storage system HSV210A controller rear view Working with hardware in HP P6000 Command View HardwareStorage system identity information Remote service testVerifying hardware status Using multiple management servers to manage arrays Updating HP controller softwareConfiguring iSCSI devices Email notification Monitoring storage system eventsEvents overview Management server event logViewing events Controller termination event logViewing additional information Configuring event notificationConfiguring host notification Filtering events by severity Applying a customized host notification listSelecting individual events Applying a customized event configuration fileRetrieving the parse file Retrieving the Management Information Base Sending the event file Creating page footer messages Configuring HP P6000 Command View advanced tasksSetting user interface options Setting audit logging options Setting a remote location for audit logsChanging port and timeout parameters Changing the login credentials array-based managementRunning HP P6000 Command View in a multi-homed environment Https//managementmoduleIPaddress2373Using the right-click menu Troubleshooting HP P6000 Command ViewRestarting the HP P6000 Command View service Optimizing performanceNavigation pane lists duplicate arrays Failed connection warning for empty controller host ports Error messages in the user interfaceFailed communication link to iSCSI devices Failed entities reported on the disk enclosureFailed transceiver Troubleshooting access to array-based HP P6000 Command ViewFailed blower power supply Failed I/O moduleVirtual disk sizes displayed incorrectly Unexpected behavior when using older Windows HBA driverStorage system connection down error message IPFilter page incorrectly displays IPv6 addressVersion numbers differ Webes 5.5 receiving events inconsistentlyComponents \Program Files\Hewlett-Packard\EVA Performance MonitorDisplaying historical state changes and performance data HP P6000 Performance Data Collector valid objecttype valuesConfiguring the HP P6000 Command View server HP P6000 Performance Data Collector objectid valuesConfiguration file for performance and state data logging Displaying HP P6000 Command View access credentialsEvents and logs Configuring HP P6000 Performance Data CollectorLogging configuration file Configuration recommendations Connecting to HP P6000 Performance Data Collector remotelyProhibited commands SSL protocolCreating the friendly names host file Using friendly namesBackward compatibility Adding friendly namesMapping worldwide names to friendly names Adding friendly names manuallyUsing short names Specifying the output Using the command line interfaceViewing arrays Refreshing dataFiltering data Specifying data output in multiple filesCommands HP P6000 Performance Data Collector commandsLuns Command modifiers HP P6000 Performance Data Collector command modifiersUsing the graphical user interface NotsPage Objects and counters Configure filteringData filtering HP EVA virtual disk HP EVA storage arrayHP EVA storage controller HP EVA virtual disk group HP EVA host connection HP EVA host port statisticsHP EVA physical disk HP EVA physical disk groupHP EVA DR tunnels HP EVA DR Group Information Related information Support and other resourcesContacting HP Document conventions Typographical conventionsWebsites Event code types and descriptions HP array event code formats and descriptionsEvent code format Software component IDsHP array event information packet EIP types Corrective action codesEvent information packet EIP types Coupled crash control codes HP array coupled crash control codesDump/restart control codes HP array dump/restart control codesGlossary EVASAN See also virtual disk Index CLIIndex 105