Sterling SDA AP-1 specifications How to Use This Manual, Safety Symbols Used in this Manual

Page 7

Chapter 1: Safety

1-1 How to Use This Manual

Use this manual as a guide and reference for installing, operating, and maintaining the large dehumidifying dryer. The purpose is to assist you in applying efficient, proven techniques that enhance equipment productivity.

This manual covers only light corrective maintenance. No other maintenance should be undertaken without first contacting a service engineer.

The Functional Description section outlines models covered, standard features, and safety features. Additional sections within the manual provide instructions for installation, pre- operational procedures, operation, preventive maintenance, and corrective maintenance.

The Installation chapter includes required data for receiving, unpacking, inspecting, and setup of the large dehumidifying dryer. We can also provide the assistance of a factory-trained technician to help train your operator(s) for a nominal charge. This section includes instructions, checks, and adjustments that should be followed before commencing with operation of the dryer. These instructions are intended to supplement standard shop procedures performed at shift, daily, and weekly intervals.

The Operation chapter includes a description of electrical and mechanical controls, in addition to information for operating the dryer safely and efficiently.

The Maintenance chapter is intended to serve as a source of detailed assembly and disassembly instructions for those areas of the equipment requiring service. Preventive maintenance sections are included to ensure that the dehumidifying dryer provides excellent, long service.

The Troubleshooting chapter serves as a guide for identification of most common problems. Potential problems are listed, along with possible causes and related solutions.

The Appendix contains technical specifications, drawings, schematics, parts lists, and available options. A spare parts list with part numbers specific to your machine is provided with your shipping paperwork package. Refer to this section for a listing of spare parts for purchase. Have your serial number and model number ready when ordering.

Safety Symbols Used in this Manual

The following safety alert symbols are used to alert you to potential personal injury hazards. Obey all safety messages that follow these symbols to avoid possible injury or death.

DANGER! DANGER indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury.

WARNING! WARNING indicates a potentially hazardous situation or practice that, if not avoided, could result in death or serious injury.

Caution! CAUTION indicates a potentially hazardous situation or practice that, if not avoided, may result in minor or moderate injury or in property damage.

Large Dehumidifying Dryers

Safety

7

Image 7
Contents SDA Large AP-1 Control Dehumidifying Dryer If the Shipment is Not Complete Shipping InfoUnpacking and Inspection Event of Shipping DamageReturns Table of Contents Operation Troubleshooting How to Use This Manual SafetySafety Symbols Used in this Manual Dryer Safety Tags Description General Responsibility ResponsibilityOperator Responsibility Maintenance Responsibility Reporting a Safety Defect Models Covered in This Manual Functional DescriptionGeneral Description Sequence of Operation Process/Regeneration CycleElectrical Features Standard FeaturesAuto Start Timer Mechanical FeaturesDewpoint Extend OptionsClosed-Loop Regeneration Drawings and Diagrams Optional dryer dust collector Process Aftercooler Aftercooler Design SpecificationsProcess Air Dust Collector Process Air Dust Collector Material Overdrying Protection Recommended Temperature SettingsElectrical Options Mechanical OptionsController Options Fail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-OutsPage Mechanical Options Denotes availability Dimensions and Specifications Denotes availabilityDenotes availability Making Electrical Connections Mechanical InstallationUncrating the Equipment Rigging and Placing UnitDescription Making Gas Line Connections Gas-Fired Models OnlyChecking Blower Rotation Checking for Proper Blower RotationDryer/Drying Hopper Process Air Connections Making Dryer/Drying Hopper Process Air ConnectionsProcess Air Heater on Drying Hopper Large Dehumidifying Dryers Mechanical Installation Aftercooler Components & Flow Rates Connecting Aftercooler/Precooler Cooling Water OptionalDrying Hopper Air Trap Using the Drying Hopper Air TrapController Description ControlsDryer Status Screen Startup Screen Process Air Temperature and Conveying Process ControllerIdentifying Controller Screens Dryer Alarms Help System LOG OFFMain Menu Screen Setting Values Dryer Menu Dryer Status Dryer Setup Over DRY Protect Alarms Auto TuneAuto Start Main Menu Dryer Setup Screen 3 Dryer Setup Screen 2Dryer Setup Screen 4 Overdry Protection Screen 1 Overdry ProtectionOverdry Protection Screen 2 Autotune Alarm History ScreenProcess AutoTune Screen Auto Start DEW Point SetupDew Point Setup Screen Autostart Timer ScreenSystem Menu System Setup SET Clock Hour Meters Alarm History StatusHelp Menu Help Menu ScreenSystem Setup Screen System Backup Service Menu Main Menu System SetupLOW Level Detection Setup Autostart Clock Screen Clock Menu ScreenOutput Status Hour Meter ScreenInput Status Input Status ScreenService System Backup ScreenService Menu Screen Alarm Screens Alarm Screen Example Redundant Safety Controller DisplayAlways put your set point to 30F above set point Setting the Redundant Safety ControllerLarge Dehumidifying Dryers Controls Start-up OperationUsing the Dryer Status Screen Alarm Descriptions AlarmsShutdown Maintenance Schedule MaintenancePhotocopy this page for your maintenance records Cleaning or Replacing the Process Air Filters Preventative MaintenanceCalibrating the Dirty Filter Alarm Cleaning or Replacing the Regeneration FilterChecking the Dewpoint Control System Symptoms of Worn Out Desiccant Corrective MaintenanceReplacing the Desiccant Replacing the Process Heater Electric Dryers Desiccant Tower AssemblyReplacing the Regeneration Heater Electric Dryers Process Heater Box AssemblyRegeneration Heater Box Assembly Basic Troubleshooting TroubleshootingIntroduction Large Dehumidifying Dryers Troubleshooting Using a Thermocouple Determining Temperature Controller Errors or Sensor ErrorsUsing a Platinum Resistance Thermometer Credit Returns Warranty ReturnsAppendix Returned Material PolicyAnnex B Information Technical SpecificationsSpare Parts List Level 3 Mechanical Components Located on back of Dryer Dryer Identification Serial Number TagSales Department Service DepartmentTechnical Assistance Parts Department