Configuring the M8521 Tape Library for the Integrity NonStop
The section covers: |
|
Supported Connection | |
Adding the Control Path and Data Path |
Supported Connection
You can attach the M8521 tape library (control path and data path) to a Fibre Channel ServerNet adapter (FCSA) on an Integrity NonStop
Note. The control path is used to control the robot, and the data path is used to control the tape drive or drives.
Adding the Control Path and Data Path
Note. To obtain the portname numbers for your control path and data path, contact a service representative from STK. The portname numbers used in this section are examples only.
To add the control path, issue this SCF command:
SCF> ADD SCSI $device, SENDTO STORAGE, PRIMARYLOCATION (group, module, slot), PRIMARYSAC
Example:
SCF> ADD SCSI $M8521, SENDTO STORAGE, PRIMARYLOCATION (110,2,2), PRIMARYSAC 2, LUN 0, PRIMARYPORT 1234567891234567